ge-interlogix simon 3 사용자 설명서

다운로드
페이지 68
Simon Security System
14
No Line Seizure
Note  
Connecting the panel to a 
standard phone (voice) line 
in this manner should be 
avoided. Other devices in 
use at the same time the 
panel is using the line can 
prevent reports from going 
through.
This method is typically used where DSL (digital subscriber line) service exists. DSL 
allows multiple devices on a single phone line to be used simultaneously. Simply con-
necting the panel LINE IN jack to an available phone jack on the premises is all that is 
required.
An in-line filter may be required to ensure panel reporting is successful.
* For UL installations, installer needs to verify line seizure.
Wiring the Power Transformer
Connect the power transformer to the panel AC terminals as shown in Figure 10.
Note  
Do not plug in the trans-
former at this time
Figure 10. Connecting the Power Transformer
Powering Up the Panel
When applying power to the panel connect the battery first, then plug in the AC power 
transformer. This sequence prevents a battery fault condition.
Installing the Panel Backup Battery
1.
Position and push the battery between the 2 flexible tabs (A in Figure 11).
2.
Slide the battery to the left until the tabs snap into place, securing the battery (B in 
Figure 11) 
Figure 11. Installing the Panel Backup Battery
3.
Connect the red and black battery leads (included with panel) to the battery and 
panel terminals (see Figure 12 A - Open Battery / B - Covered Battery).
Connecting the Battery Leads to the Battery and Panel Terminals (see Figure 12).
H W I N 2
H W I N 1
D C O U T
A C
A C
+
-
+-
+-
+
-
Tabs