Simon Security System
25
Delete—Option #—16—DONE.
Option 17: Dialer Delay (Default = off)
Determines whether the panel delays dialing programmed phone numbers before send-
ing reports (on), or if dialing begins immediately (off).
If Option 21: Opening (Disarming) Reports is on, the panel does not delay dialing if the 
system is disarmed before the delay time expires. The panel dials immediately for both 
the alarm and opening report.
Note  
Regardless of this option setting, the panel always dials immediately for alarms from sensors 
in groups 0-8, 26, for alarms triggered by the control panel or remote handheld touchpad 
emergency buttons, and for programming, AC power failure, and low battery reports.
The delay time can be set from 005 - 254 seconds (015 to 045 if Option 69: SIA Limits 
is on). Entries must be 3 digits.
Note  
For UL installations, the 
Dialer Delay must not 
exceed 45 seconds.
¾
To set Dialer Delay, press:
Add—Option #—17—005 - 254—DONE.
¾
To turn off Dialer Delay, press:
Delete—Option #—17—DONE.
Option 18: Alarm Cancel Report (Default = 005 minutes)
Sets the time frame that determines whether the panel reports an alarm cancel message 
to the central station.
If the system is disarmed from an alarm state within the programmed time, the panel 
sends an alarm cancel message to the central station. An alarm cancel message is not 
reported if the system is disarmed after the programmed time expires.
The time can be set from 005 - 255 minutes. Entries must be 3 digits. When set to 255, 
the panel always reports alarm cancel messages. Turning off this option disables alarm 
cancel reporting.
¾
To turn on Alarm Cancel Report, press:
Add—Option #—18—005 - 255—DONE.
¾
To turn off Alarm Cancel Report, press:
Delete—Option #—18—DONE.
Option 19: RF Timeout (Default = 12 hours)
Determines the time period the panel must receive at least one supervisory signal from 
learned sensors before identifying a sensor failure and sounding trouble beeps. Any sen-
sor failure is reported immediately and again at the supervisory time (Option 72: Super-
visory Time).
The timeout can be set from 02-24 hours. Entries must be 2 digits.
Note  
Setting this feature to 2 
hours (02) may cause false 
reports. For UL 985 and 
1635 listed systems, RF 
Timeout must be set to 4 
hours (04). For UL 1023 
listed systems, RF Timeout 
must be set to 24 hours (24).
¾
To change RF Timeout, press:
Add—Option #—19—02 - 24—DONE.
¾
To reset RF Timeout (return to default), press:
Delete—Option #—19—DONE.
Option 20: Manual Phone Test (Default = on)
Determines whether the user can perform a manual phone test to verify communication 
to a central station/pager (on), or not (off).
¾
To turn on Manual Phone Test, press:
Add—Option #—20—DONE.