ge-interlogix simon 3 사용자 설명서

다운로드
페이지 68
Simon Security System
31
Option 41: Chime Voice (Default = off)
Determines whether the panel announces the sensor number and name (on) or only 
sounds beeps (off), when the CHIME Doors or CHIME Special Motion features are on 
and sensors in groups 10, 13, and 25 are tripped while the system is disarmed.
¾
To turn on Chime Voice, press:
Add—Option #—41—DONE.
¾
To turn off Chime Voice, press:
Delete—Option #—41—DONE.
Option 42: Speaker Level (Default = 8)
Sets the volume of voice messages from the panel speaker.
The volume can be set from 1 (lowest) to 8 (highest). Turning off this option returns the 
setting to the default value.
¾
To set Speaker Level, press:
Add—Option #—42—1 - 8—DONE.
¾
To turn off Speaker Level (return to default), press:
Delete—Option #—42—DONE.
Option 43: Numeric Pager/Voice Event Notification Phone Number 
(Default = off)
Note  
Some pagers may require 3 
or 4 additional pauses after 
the last digit to work cor-
rectly.
Lets you program up to a 26-digit phone number for numeric pager or voice event noti-
fication (on), or delete an existing phone number (off).
When used to call a numeric pager, a 3-digit code appears on the pager display to iden-
tify the report. When used to call a remote phone, a person at the remote phone location 
can hear system voice alarm announcements. See the “Testing” section for more infor-
mation.
Press Test for each required pause, Add for a *, and Delete for a # (each of which uses 
one of the 26 available places).
Note  
Pressing DONE is required if 
you enter fewer than 26 dig-
its. The phone number is 
automatically stored without 
pressing DONE if all 26 
places are used.
¾
To set Numeric Pager/Voice Event Notification Phone Number, press:
Add—Option #—43—Up to 26 digits—DONE.
¾
To delete Numeric Pager/Voice Event Notification Phone Number, press:
Delete—Option #—43—DONE.
Option 44: Numeric Pager/Voice Event Notification Phone Mod 3 
(Default = 09)
Determines the report content and reporting format when Option 43: Numeric Pager/
Voice Event Notification Phone Number is programmed. The following table describes 
the choices. All entries must be 2 digits.
¾
To set Numeric Pager/Voice Event Notification Phone Mod 3, press:
Add—Option #—44—08, 09, or 10—DONE.
Phone Mod 3
Setting #
Content
Format
08
Latchkey, No Activity, Phone Test, Openings, 
Closings, Fail to Open/Close, AC Power Resto-
rals/Failures
Numeric Pager
09
Same as setting 8 plus Alarms
Numeric Pager
10
Alarms and Latchkey only
Voice Event Notification