ge-interlogix simon 3 사용자 설명서

다운로드
페이지 68
Simon Security System
29
Delete—Option #—33—DONE.
Option 34: Fail to Open Report (Default = off)
Determines whether the panel sends a Fail to Open report to a central station or pager if 
the system has not been disarmed by the programmed time (on), or not (off).
Note  
System time must be set 
correctly for this feature to 
work.
¾
To turn on Fail to Open Report, press:
Add—Option #—34—Hours—Minutes—DONE.
¾
To turn off Fail to Open Report, press:
Delete—Option #—34—DONE.
Option 35: Fail to Close Report (Default = off)
Determines whether the panel sends a Fail to Close report to a central station or pager if 
the system has not been armed by the programmed time (on), or not (off).
Note  
System time must be set 
correctly for this feature to 
work.
¾
To turn on Fail to Close Report, press:
Add—Option #—35—Hours—Minutes—DONE.
¾
To turn off Fail to Close Report, press:
Delete—Option #—35—DONE.
Option 36: Sensor Activated Light Lockout Start Time (Default = off)
Sets the START time that determines when the panel prevents the sensor activated 
lights feature from turning on sensor activated lights.
Note  
System time must be set 
correctly for this feature to 
work.
When a time value is set (on) and the sensor activated lights feature is on, the panel pre-
vents sensor activated lights from turning on between the programmed start time (this 
option) and the programmed stop time (Option 37).
Note  
Both Options 36 and 37 
must have a time pro-
grammed for this feature to 
work correctly.
When both Options 36 and 37 are turned off and the sensor activated lights feature is 
on, sensor activated lights turn on at all times.
¾
To set Sensor Activated Light Lockout Start Time, press:
Add—Option #—36—Hours—Minutes—DONE.
¾
To turn off Sensor Activated Light Lockout Start Time, press:
Delete—Option #—36—DONE.
Option 37: Sensor Activated Light Lockout Stop Time (Default = off)
Sets the STOP time that determines when the panel prevents the sensor activated lights 
feature from turning on sensor activated lights.
Note  
System time must be set 
correctly for this feature to 
work.
When a time value is set (on) and the sensor activated lights feature is on, the panel pre-
vents sensor activated lights from turning on between the programmed start time 
(Option 36) and the programmed stop time (this option).
Note  
Both Options 36 and 37 
must have a time pro-
grammed for this feature to 
work correctly.
When both Options 36 and 37 are turned off and the sensor activated lights feature is 
on, sensor activated lights turn on at all times.
¾
To set Sensor Activated Light Lockout Stop Time, press:
Add—Option #—37—Hours—Minutes—DONE.
¾
To turn off Sensor Activated Light Lockout Stop Time, press:
Delete—Option #—37—DONE.
Option 38: Auto Arm (Default = off)
Determines how long the system protests (announces open/failed sensors) when 
attempting to arm with open/failed sensors, before bypassing these sensors and auto-
matically arming the rest of the system.