Option 65: No Usage Report (Default = off)
Determines whether the panel sends a No Usage report to the central station if the user 
has not operated the system before the programmed time expires (on) or not (off). The 
timer starts each time the system is disarmed.
This is a customer service feature that alerts the central station if a customer is not using 
their security system. The service provider can then contact the customer to find out 
why the system is not being used, and help correct any problems for the customer.
The time can be set from 001 to 254 days. Entries must be 3 digits.
¾
To turn on No Usage Report, press:
Add—Option #—65—001 - 254—DONE.
¾
To turn off No Usage Report, press:
Delete—Option #—65—DONE.
Option 66: External Siren Delay (Default = off)
Determines whether external siren activation is delayed 30 seconds after an alarm 
caused by a delayed sensor (on), or if external siren activation is immediate upon alarm 
activation (off).
¾
To turn on External Siren Delay, press:
Add—Option #—66—DONE.
¾
To turn off External Siren Delay, press:
Delete—Option #—66—DONE.
Option 67: Quick Exit (Default = off)
Determines whether pressing the Disarm button when the system is armed activates the 
exit delay time to allow exit and re-entry without disarming the system (on) or not (off).
This feature is useful if the user wants to step outside briefly and return, such as to get 
the paper. If the system is armed and the user presses the Disarm button, the panel 
announces “Exit time on” and sounds exit delay beeps. This allows a designated entry/
exit door to be open for up to 2 minutes without causing an alarm. When the door is 
closed, the beeps stop and the door is armed again.
Note  
For UL listed systems, Quick 
Exit must be off.
¾
To turn on Quick Exit, press:
Add—Option #—67—DONE.
¾
To turn off Quick Exit, press:
Delete—Option #—67—DONE.
Option 68: Swinger Shutdown (Default = on)
Determines whether the panel prevents the same sensor from activating an alarm more 
than once in a single arming period (on) or not (off).
Note  
Swinger Shutdown does not 
affect smoke and fire sen-
sors.
¾
To turn on Swinger Shutdown, press:
Add—Option #—68—DONE.
¾
To turn off Swinger Shutdown, press:
Delete—Option #—68—DONE.
Option 69: SIA Limits (Default = on)*
Determines whether Entry, Exit, and Dialer delay times fall within SIA limits (on) or 
factory ranges (off).
The following table shows the available settings when this option is on or off
.