Simon Security System
38
Note  
If options 10, 11 or 17 are 
set outside the SIA limits 
while Option 69 is OFF, turn-
ing Option 69 ON will not 
affect options 10, 11 or 17 
until they are manually 
changed.
¾
To turn on SIA Limits, press:
Add—Option #—69—DONE.
¾
To turn off SIA Limits, press:
Delete—Option #—69—DONE.
* Not investigated for use by UL.
Option 70: Not Available
Option 71: Programming Report (Default = off)
Determines whether the panel sends a report to the central station anytime the pro-
gramming mode is entered/exited (on) or not at all (off).
The panel sends a report whenever the dealer (Utility 1) or installer (Utility 2) code is 
used to enter programming mode and another report is sent when the programming 
session ends (when the cover is closed).
¾
To turn on Programming Report, press:
Add—Option #—71—DONE.
¾
To turn off Programming Report, press:
Delete—Option #—71—DONE.
Option 72: Supervisory Time (Default = 12:00am)
Determines when the panel reports supervisory conditions (sensor failures) and auto-
matic phone tests to the central station.
Note  
The panel clock must be set 
to the correct time for this 
option and Option 16: Auto 
Phone Test to work correctly.
¾
To set Supervisory Time, press:
Add—Option #—72—Hours—Minutes—DONE.
¾
To turn off (disable) Supervisory Time, press:
Delete—Option #—71—DONE.
Option 73: Modem Sensitivity (Default = off)
Determines whether the modem sensitivity is set to normal (off) or high (on).
Note  
This feature should be used 
only if the panel experiences 
consistent trouble reporting 
to the central station. Other-
wise, leave this option off.
¾
To turn on Modem Sensitivity, press:
Add—Option #—73—DONE.
¾
To turn off Modem Sensitivity, press:
Delete—Option #—73—DONE.
Option 74: Silent Panel Police Panic (Default = off)
Determines whether pressing the panel police panic button causes an audible (off) or 
silent (on) alarm.
SIA Limits
Affected Option
SIA Limits 
(Option 69 on)
Factory Ranges 
(Option 69 off)
Option 10: Entry Delay
030-254 seconds
005-254 seconds
Option 11: Exit Delay
045-254 seconds
005-254 seconds
Option 17: Dialer Delay
015-045 seconds
005-254 seconds