JBL Commercial JBL CSMA 280 사용자 매뉴얼

다운로드
페이지 34
 17
2.3 Ensuring Proper Cooling
When using an equipment rack, keep a minimum space of 4 inches (10cm) from the 
top surface of the unit.  Close any open spaces in the rack with blank panels.  DO 
NOT block any air vents.  The side walls of the rack should be a minimum of 2 inches 
(5 cm) from the amplifier sides.  The back of the rack should be open.
2.4 Choosing Input Wire and Connectors
We recommend using pre-built or professionally wired balanced line (two-conductor 
plus shield) 22-24 gauge cables to connect the amplifier balanced input by using the 
included Euroblock connectors, see Figure 2.4. Unbalanced lines may be used, but 
may result in hum or RF noise very long cable runs.
You can also use RCA connectors to connect audio devices, for example, CD/DVD 
player. However, do not use both Euroblock and RCA audio input connectors on a 
single channel at the same time.
NOTE: Custom wiring should only be performed by qualified personnel.
MONO SUM
AUDIO
SOURCE
AUDIO
SOURCE
AUDIO
SOURCE
AUDIO
SOURCE
Figure 2.4.1 Input Wiring
Note: Two RCA connectors are provided for summing left and right channels from a 
stereo source.  Do not use both Euroblock and RCA connectors concurrently for any 
single input channel.