dresden elektronik ingenieurtechnik gmbh MEGA22M00 사용자 설명서

다운로드
페이지 52
User Manual 
Version 1.1c 
2013-07-01 
 
OEM
 
radio modules deRFmega 
 
 
 
 
 
www.dresden-elektronik.de 
 
Page 16 of 52 
 
4.4. 
Output power and duty cycle settings for deRFmega128-22M12 
The  radio  module  deRFmega128-22M12  is  able  to  provide  an  output  power  greater  than 
20dBm. Table 4-8 defines the necessary power  settings of the TX_PWR register  [1], which 
must  be  set  to  fulfill  all  national  requirements  of  Europe  (EN  300  328)  and  USA  (CFR  47 
Ch. I  FCC  Part  15).  The  duty  cycle  defines  the  relationship  between  the  radio-on  time  and 
the period of 100ms. 
 
Channel 
ETSI 
FCC 
TX_PWR 
[hex] 
Duty Cycle 
[%] 
TX_PWR 
[hex] 
Duty Cycle 
[%] 
11 
0x0E 
100 
0x0B 
100 
12 
0x0E 
100 
0x02 
100 
13 
0x0E 
100 
0x01 
100 
14 
0x0E 
100 
0x00 
100 
15 
0x0E 
100 
0x00 
100 
16 
0x0E 
100 
0x00 
100 
17 
0x0E 
100 
0x00 
100 
18 
0x0E 
100 
0x00 
100 
19 
0x0E 
100 
0x00 
100 
20 
0x0E 
100 
0x00 
100 
21 
0x0E 
100 
0x00 
100 
22 
0x0E 
100 
0x00 
100 
23 
0x0E 
100 
0x06 
100 
24 
0x0E 
100 
0x0D 
100 
25 
0x0E 
100 
0x0F 
100 
26 
0x0E 
100 
0x0F 
30 
Table 4-8: power table for deRFmega128-22M12