Atech OEM Inc. WM100X 사용자 설명서

다운로드
페이지 21
    iWEM-1000UM, Dec 30, 2010
 
Atech Technology Co., Ltd. 
7F, AAEON Building, No.43, Sec. 4, Keelung Rd, Taipei City 10607, Taiwan (R.O.C.) 
Tel: +886-2-2377-0282 
Fax: +886-2-2377-0283 
http://www.atechoem.com/
 
Host IP: 192.168.2.254 
Remote port: 2000 
Protocol: 1 (TCP client) 
 
5. Default 
Setting 
The following sections describe the default settings when iWEM-1000 is out of Atech factory. The user can 
issue set_factory_defaults to put the module back to factory default settings. The user can also toggle the 
factory default pin in specified sequence to put iWEM-1000 into factory default settings. 
5.1. WLAN 
SSID: atech 
802.11 Channel: 1 
Mode: Infrastructure 
Antenna: 0 
Security: WPA-PSK 
WPA Password: 12345678 
Preferred Data Rates: 24M, 12M, 5M, 1Mbps 
5.2. Network 
DHCP: ON 
Remote TCP server: 192.168.0.100 
Remote TCP server port to connect: 2000 
Local IP address: 0.0.0.0 
Local port: 1000 
Netmask: 255.255.255.0 
Gateway: 0.0.0.0 
Protocol: TCP client 
5.3. UART  
Baudrate: 9600 
Flow control: No flow control 
MTU: 1400 bytes 
Flush Timeout: 10 ms