Operation 
 
 
52  
 
EverGuard Control Panel 
 
5.  Under Power, set the indicators that notify the monitoring station of power 
failure for the following parameters: 
  Random time for 220v fail indication – Enables or disables the 
random time message that is sent to the monitoring station. This sends a 
message at random time intervals to the monitoring station along with 
the fixed time message. For multiple panels (e.g., in an apartment 
building), it is recommended to set random time to send a message. 
  220v indication delay timeout – Defines the fixed time message to be 
sent (in minutes). The master clock, after a delay, sends a message to 
the monitoring station regarding a power failure. 
  Range limit for 220v fail Random - Sets the random message to be 
sent (in minutes). This parameter can only be configured if the Random 
time for 220V fail indication 
parameter is enabled. It is recommended 
to set this parameter for the value of that set for Random time for 
220v fail indication
 + an additional 5 min. 
6.  Press the Automatic Configuration button to set the automatic RF output 
activation in each of the following system states: 
  ALARM 
  PANIC 
  ARM 
  DISARM 
  DURESS 
From the Device dropdown list, select one of the following: 
  X-10 devices - can handle stronger appliances (e.g., washing machine, 
etc.) 
  RF Output devices - generally is set for lights. Assign assigned an ID 
number. The range is 1 to 16. 
7.  Under Password, configure the following codes: 
  Duress Pin-Code – Enter a 4 digit code to trigger dispatching a duress 
message to the control center. 
  ESI-CMS DTMF Code – Enter a 4 digit code to activate external devices. 
8.  Localization – Set the source for the control panel real-time-clock. Select 
enable to sync with the GSM network clock or disable to sync with the 
monitoring station server. 
For compliance with the EN 50131 standard, set Synchronize Clock from 
GSM
 to enable
The Panel local Time parameters are read-only and are drawn from the 
system. 
9.  Set the Periodic Test Period, in days, hours, minutes, how often the system 
should send a test message to the control center. 
Note that for compliance with the EN 50131 standard, this test should be 
enabled and set to a period of not more than 2 hours. 
10.  Set the Transmitter parameters according to requirements: 
  GSM Module – Enables or disables the GSM module.