S and C Electric INTELLICOM 사용자 설명서

다운로드
페이지 16
 
                                                      S&C Instruction Sheet 1069-500      7
Tools Needed
You will need:
•  #2 Phillips screwdriver. 
•  Small adjustable wrench.
•  Wire cutters to cut tie wraps around cables.
•  Weatherproofing kit 
Depending on the installation location, you may need ladders, a 
lift truck, or other means to access the actual installation loca-
tions.
Preparing Earth Ground
The S&C IntelliCom WAN 1720 mesh radio must be properly con-
nected to earth ground. Failure to do so may result in equipment 
damage, injury, or death. The product warranty does not cover 
damages resulting in part or in whole from improper grounding. 
Consult your location’s building and electrical codes regarding 
antennas and follow them, or consult the National Electric Code 
(NEC).
•   If connecting to a tower or pole, connect the base of the 
tower pole directly to the building’s ground or to one or more 
approved grounding rods using 10 AWG ground wire and 
corrosion-resistant connectors.
•   Connect the grounding cable to rain gutters only if the  
rain gutter is connected to earth ground.
•   Ground rods should be copper-plated, 1.8 - 2.4 m (6 - 8 ft) 
long.
•   Install all grounding components in straight lines. If bends are 
unavoidable, do not make sharp turns.
•  Earth-to-ground should not be more than 10 ohms.
•  Understanding the soil is very important in order to create a 
proper earth ground. If your soil is rocky or sandy, drive your 
ground rods and then pull them back out and dump an ap-
proved ground enhancement material into the holes where the 
grounding rods go. Then replace the grounding rods. Keep in 
mind that some salt compounds are corrosive and can cause 
copper to corrode. 
Antenna Placement
S&C recommends the use of antennas specifically designed for 
MIMO applications. While it is possible to select and mount six 
individual antennas, determining correct placement and spacing 
is difficult. Use an antenna engineered for best results with MIMO.
Setup and Installation
F
igure
 3.1 
 S&C IntelliCom 
WAN 1720 AC Connector
1-neutral
2-line
3-ground
AC Power 
Cable-End View
1-neutral 2-line
3-ground
AC Power 
Connector View
This shows the pinout of the 
AC Power connector used on 
outdoor nodes. Views are shown 
of both the connector on the unit, 
and the mating connector on the 
cable itself. Pin 1 is neutral; pin 2 
is line, and pin 3 is ground.
F
igure
 3.2 
 S&C IntelliCom 
WAN 1720 DC Connector
5
6
1
2
ground
power
Cable-End View 
5
6
1
2
Connector View 
3
4
3
4
power
This shows the pinout of the DC 
power connector used on outdoor 
nodes. Each view is of the cable 
connector, as viewed end-on. 
Pins 3 and 4 are ground. Pins 1 