Custom­izing the Setup 
30
 29
  CULLIGAN GLOBAL ELECTRONIC CONTROLLER
Regeneration Set-up
• 
Press the UP
  
„ 
or DOWN
  
‰ 
arrow to scroll to menu item
• 
Press the CHECKMARK
   
key to select a menu item
•  Press the 
UP
   
„ 
or 
DOWN
  
   
arrow to change a selection
• 
Press the CHECKMARK
   
key to save your selection
Default Values are shown for each selection
Scroll to 
ADV SETUP
 and select
Select 
REGEN SETUP
This value is the salt dosage in pounds (LBS) for 
US INCH
 (total number of pounds of salt used 
per regeneration). The salt dosage contributes to calculating the resin capacity and is also used 
when a Smart Brine Tank Sensor is installed to help calculate salt usage and salt remaining. The 
higher the salt dosage the higher the capacity. Refer to the appendix of the unit’s installation 
manual for information on setting the salt dosage.
For example, for a CSM 300-2 (10 ft³ of resin), and a desired capacity of 250,000 grains, the 
chart in the manual shows the dosage at 102 pounds.
This setting is generally used for a single-delay system. For a multi-tank system, reserve capacity is 
not necessary and should be set to zero (0). If you do not change this value in a multi-tank system, 
your unit will regenerate when 30% of the capacity remains.
This setting is used for time clock regeneration. This is the time of day that the unit will regenerate 
when needed.
Select either 
DELAYED
 or 
IMMEDIATE
. For multi-tank systems, this is normally set to 
IMMEDIATE
. If immediate is selected, be sure to change the Reserve Capacity setting.
Use this setting to prevent back-to-back regenerations on multi-tank systems, if necessary. When 
one unit is done regenerating, the next regeneration cannot begin until the set amount of time has 
passed.
This concludes the Regeneration Set-Up section. Continue to press the 
X
 key until reaching the Main Menu.
 
 > 5) Adv Setup
system ok
7:32 am 2-1-08
 > 2) regen Setup
salt dosage
9.0 lbs
reserve capacity
30%
Customizing the Setup
Time of regen
2:00 AM
regen mode
delayed
Regen lockout
for 0 hours