Culligan International Company 01020553 사용자 설명서

다운로드
페이지 74
 
Custom­izing the Setup 
32
 31
  CULLIGAN GLOBAL ELECTRONIC CONTROLLER
 
Regeneration Triggers
• 
Press the UP
  
„ 
or DOWN
  
‰ 
arrow to scroll to menu item
• 
Press the CHECKMARK
   
key to select a menu item
•  Press the 
UP
   
„ 
or 
DOWN
  
   
arrow to change a selection
• 
Press the CHECKMARK
   
key to save your selection
Default Values are shown for each selection
Scroll to ADV SETUP and select
Select REGEN TRIGGER
This setting requires an optional flow meter (except Hi-Flo 22) or optional Aqua-Sensor. 
Use this setting to tell the controller whether the optional flow meter  or Aqua-Sensor is 
used to trigger a regeneration. If set to CAN TRIGGER, the flow meter is used to count 
the gallons of soft water until the batch value is reached, at which time a regeneration 
is triggered. You can install water meter and use it just to monitor flow rate and total 
usage, and not use it to trigger the regeneration. An Aqua-Sensor device (softeners) or 
differential pressure switch (filters) can be used to trigger the regeneration. You can have 
both the water meter and Aqua-Sensor/differential pressure installed and able to trig-
ger regeneration. Either one can trigger the regeneration and everything is reset when 
regeneration is complete.
Use this setting if using time clock regeneration only or if you would like to have a time 
clock backup for the installed trigger device. It is common to set this at 3 days, although 
not necessary.
The Predict Mode is used in the flow meter mode to determine the optimum regeneration 
point. Before the regeneration starts, the control will compare the remaining capacity 
value with the average daily water use. If the average daily water usage is less than the 
remaining capacity, the controller will wait 24 more hours be3fore regeneration. If the 
remaining capacity is less than the average daily water usage, the control will initiate 
regeneration. This works in delay mode only. At any time, if the total capacity value is 
reached, the control will initiate an immediate regeneration.
Use this setting to select the days of the week to regenerate. This is most useful when 
running the system as time clock only. For commercial multi-tank systems, leave all days 
to OFF.
The program will go through the rest of the days of the week to set regeneration on or 
off.
This concludes the Regeneration Trigger section. Continue to press the X key to return to the Main Menu.
 > 5) Adv Setup
system ok
7:32 am 2-1-08
 > 4) Regen Trigger
flow meter
can trigger
regen intervals
number of days: 0
predict mode
>
off
regeneration on monday
>off
Customizing the Setup
regeneration on monday, ...  
>off
Aqua sensor
can trigger