605-0000-707 ProST 49 Installation User Guide-Rev C 
38 
 
Connecting the Lightning and Surge Protector 
The third-party (PolyPhaser) lightning and surge protector for the SDA-1 is implemented in the 
following deployment scenarios: 
 IDU/ODU cable connectivity of 40 meters or more (mandatory)  
 Deployment of ProST in geographical areas that often experience severe lightning 
storms 
The lightning and surge protector protects the CAT 5's six used wires (two -48 VDC wires and 
four Ethernet Tx and Rx wires) from any electrical surge due to a lighting strike.  
The protector is installed outdoors on the CAT 5 cable that connects between the ProST and 
SDA-1. In other words, two CAT 5 cables are required: one for the protector-to-ProST 
connection and the other for the protector-to-SDA-1 connection. 
Warning:  Do not install the lightning and surge protector during adverse weather 
conditions when the threat of lightning strike is possible. 
 
To install the protector: 
1.
 
Connect the protector in the direction according to the labels. The end labeled SURGE 
accepts the cable from the ProST; the end labeled PROTECTED  accepts the cable from 
the SDA-1.