Chapter 4  Operation 
AirMux-104 Installation and Operation Manual 
4-2 Operating 
AirMux-104
 
 
Table 4-2.  RT LEDs 
Name Function 
Location 
RSS/SNR  
(triple yellow LED) 
ON (AirMux-104 units are not synchronized) – Received signal 
strength 
ON (AirMux-104 units are synchronized) – Signal-to-Noise 
ratio 
RT 
LINK  
(square green LED) 
OFF – AirMux-104 units are not synchronized 
ON – AirMux-104 units are synchronized 
RT 
STATUS  
(circular green LED) 
Blinks slowly – AirMux-104 units are not synchronized 
Blinks rapidly – AirMux-104 units are synchronized 
RT 
4.2 Operating AirMux-104 
Turning On AirMux-104 
 
To turn on AirMux-104: 
•  Connect the AC/DC converter to the RTCB power connector and to the mains. 
The PWR indicator lights up and remains lit as long as the RTCB receives 
power. 
AirMux-104 requires no operator attention once installed, with the exception of 
occasional monitoring of front panel indicators and statistics data. Intervention is 
only required when AirMux-104 must be configured to its operational 
requirements, or diagnostic tests are performed. 
Normal Indications 
Upon turning on AirMux-104, the PWR LED in the front panel lights to indicate 
that AirMux-104 is on. 
 shows the correct status of the indicators a few 
seconds after power-up. 
Table 4-3.  AirMux-104 Indicator Status 
Indicator Status 
PWR ON 
RTCB ON 
If the above LED indications do not appear following initial power turn-on, refer to 
 for the diagnostic test instructions. 
Turning Off AirMux-104  
 
To turn off AirMux-104: 
•  Remove the AC/DC converter power cord from the mains.