WIRING INSTRUCTIONS
1. 
Disconnect power to the circuit by turning the circuit 
breaker OFF before installation.
WARNING
TURN THE POWER OFF AT THE CIRCUIT
BREAKER BEFORE INSTALLING THE DIMMER.
2. 
Strip existing wire ½” (12.7mm). 
3. 
Wire the LINE (black), NEUTRAL (white) and LOAD lead 
wires to the supply/load wires per Figure 2. If installing 
in a grounded metal box, the unit will be grounded to 
the electrical box. Otherwise, use the green ground 
screw to connect to ground as shown in Figure 2. Use 
#12AWG copper wire. Depending on the application and 
the number of connections, more space may be needed. 
If so, use an appropriate size box or box extension.
4. 
If the MR2000 will be controlled by a wired multilocation 
controller (MCD68/DCD68) connect the yellow traveler 
wire per the instructions provided with the controller. 
If using the MR2000 in a Miro wireless network, the 
yellow traveler wire is not used and must be capped. 
5. 
Switch the circuit breaker back ON.
6. 
If the unit is to be controlled from a Miro wireless 
device, refer to “SET HOUSE ID” on the next page. 
INSTALL IN COMPLIANCE WITH ALL APPLICABLE CODES 
& STANDARDS. Failure to follow these instructions 
may cause personal injury or equipment damage.
Load
Wires
Supply
Wires
Multilocation
Controller
Traveler  (YEL)
Ground 
Neutral (WHT)
Line (BLK)
Load (RED)
Wire Legend
GND
(Connect 
to 
building 
ground) 
Max. traveler wire 200' (60m)
GND
Figure 2 - Wiring Diagram
A Miro 2000W Dimmer is compatible with wired Miro devices, 
as shown above connected by a traveler wire between the 
MR2000 and the Multilocation Controller (either MCD68 
or DCD68). It will also communicate with a wireless Miro 
network (see Figure 1).
Call 800-879-8585 for Technical Support
www.wattstopper.com
INSTALLATION
The unit must be installed in compliance with the 
Environment and Orientation instructions.
CAUTION
Disconnect power when servicing fixture
or changing lamps. Both lighting fixture 
and dimmer must be grounded. Use 
this device only with copper wire.
Radio communication cannot be guaranteed if the unit is 
mounted in a metallic electrical enclosure. 
1. 
Install dimmer in a 2¹⁄
8
” minimum deep 4” square (1900) 
electrical box with a 1½” extension. Extension must 
extend beyond wall such that the heatsink is spaced a 
minimum of 1½” from the wall.
2. 
For both wall and plenum mounting, orient the dimmer 
so that the heat sink fi ns run vertically, allowing natural 
upward convection. 
3.   Allow a minimum of 6” space above and below the unit 
and do not block vertical airfl ow through the heat sink. 
Requires 100 BTU/hour ventilation.
Figure 3 - Mounting Diagram 
OPERATION
 
• When 
you 
see 
 in the instructions, press the top 
button on the MR2000, or the top of the paddle when 
referencing other Miro devices.
• When 
you 
see 
 in the instructions, press the bottom 
button on the MR2000, or the bottom of the paddle when 
referencing other Miro devices.
• When 
you 
see 
 in the instructions, simultaneously 
press and hold BOTH the UP and the DOWN buttons on 
the MR2000 (or, when referencing other Miro devices, 
fi rmly press and hold BOTH the top and bottom of the 
device paddle).
1 tap = last used level
2 taps = full output
Press and hold = raise light 
level
1 tap = fade to OFF
Press and hold = reduces 
light level
Figure 4: 