Figure 4-3 
QUPID Sensor Detection Test 
 
 
4.6 
Conduct sensor walk test to verify detection zone as illustrated in Figure 4-3. 
 
NOTE:   To properly test range gate detection, the tester must begin the test 15 
meters beyond the range gate setting.  For example, to test for detection at 100 
meters, the intruder must begin approaching QUPID at a distance of 115 meters.  
To detect an intruder presence at the 70 meter range setting, begin the test at 85 
meters. To test at a 30 meter setting, begin at 45 meters. 
 
In all cases the intruder must continue moving through all three range gates in their 
entirety.  That is, the tester must continue walking or belly crawling through the 
gates until the QUPID alarms.  This may require the tester to continue movement 
until reaching the innermost boundary of the last (“C”) gate which is the gate 
boundary closest to the QUPID. 
 
See details in 
Section 5.0
 about range setting and clearance distances. 
Degrees Left 
Degrees Right 
40° 
40° 
30° 30° 
20° 20° 
10° 10° 
0° 
45° 
45° 
(ALARM) 
Centerline 
(Boresight) 
QUPID Sensor 
Range Gates