Configuring the Door Control Unit 
 
InfoProx Entry   
Contrast 
The first screen in the unit setup sequence is Contrast.  
 
To alter the contrast 
1. 
From the Configure Reader screen, press twice to continue to the 
Contrast screen.  
The following prompt appears: 
 
Alter Contrast 
1 + 2 -# Exit 
2. 
Press 1 to set a darker display. 
3. 
Press 2 to set a lighter display. 
4. 
Press # to move to the next screen: Door Mode
Door Mode 
Two door modes are available: 
·  Door Reader: the standard door mode for a reader controlling access 
at a door. When the reader is configured as a door reader, three of the 
four inputs are reserved for door position, lock status and request to 
exit, leaving one spare input. 
·  Control Post Reader: a door mode used to validate cards, normally at 
a manned control point having no physical barrier or door.  
To configure the door mode 
1. 
From the Configure Reader screen, press the key three times to 
continue to the door mode prompt.  
The following prompt appears: 
 
Ù
 Alter  # Exit 
Door Reader 
2. 
Press 
Ù to change between the door modes. 
3. 
Press # to confirm the selection and move to the next screen. 
 