Controlled Electronic Management Systems Ltd INFOPROX 사용자 설명서

다운로드
페이지 79
InfoProx Entry   
 
Diagnostic Routine 
Displaying Diagnostic Screens 
The following sequence provides a read-only view of screens that provide 
information about the current InfoProx Entry unit setup and configuration.  
 
Enter 
Ù to start the automatic diagnostic routine, as above, 
and to move through the following diagnostic screens. Each 
screen in the sequence will be titled Current Setup or 
Diagnostic Tests. Once the routine is started, it can only be 
stopped by shutting off the unit’s power. When the routine is 
finished, it returns the user to the Administration menu. 
 
To display diagnostic screens 
Relay idle state:  
 
Current Setup 
RO N/C 
On this screen, the relay is configured as N/C (normally closed), opening 
when a valid transaction is initiated (i.e., presenting a valid card). 
Keypad is enabled. If keypad entry is setup, this screen will appear: 
 
Current Setup 
    Keypad. 
Door is controlled: 
 
Current Setup 
Door Reader 
 
On this screen, the reader is configured to control a 
door. By default for a door reader, input 0 monitors 
door position and input 1 monitors lock position. Input 
2 is for an egress button, while input 3 is unassigned. 
Indicates whether the reader has a slave device (exit reader unit) 
attached and/or is connected to a DIU (Door Interface Unit): 
 
Current Setup 
SLAVE N  DIU N 
Number of cards currently in the database: 
 
Diagnostic Tests 
Cd37    Fr57304 
In this example, there are 37 cards in the database and room for 57304 
more. The total capacity of the database is 57341 cards. Numbers are 
displayed in decimal format. 
 
Software House 
 
57