2.2  RF  Antenna  Interface 
22
 
2.2.1 
Antenna Installation 
The antenna is connected by soldering the antenna pad (ANT_GSM, i.e., pad #59) and its 
neighboring ground pads (GND, i.e., pads #58 and #60) directly to the application’s PCB. The 
antenna  pad  is  the  antenna  reference  point  (ARP)  for  EHS6-A.  All  RFd  ata  specified 
throughout this document is related to the ARP. 
The distance between the antenna ANT_GSM pad (#59) and its neighboring GND pads (#58, 
#60)  has  been  optimized  for  best  possible  impedance.  On  the  application  PCB,  special 
attention should be paid to these 3 pads, in order to prevent mismatch. 
The wiring of the antenna connection line, starting from the antenna pad to the application 
antenna should result in a 50
 
 line impedance. Line width and distance to the GND plane 
needs to be optimized with regard to the PCB’s layer stack.  
To prevent receiver desensitization due to interferences generated by fast transients like high 
speed clocks on the application PCB, it is recommended to realize the antenna connection 
line using embedded Stripline rather than Micro-Stripline technology.  
For type approval purposes, the use of a 50
 
 coaxial antenna connector (U.FL-R-SMT) might 
be necessary. In this case the U.FL-R-SMT connector should be placed as close as possible 
to EHS6-A‘s antenna pad.