Gemalto M2M GmbH EHS6-A 사용자 설명서

다운로드
페이지 41
Cinterion
®
 EHS6-A Hardware Interface Overview 
Page 19 of 41
 
2.1 Application Interface 
22
 
 
EHS6-A_HIO_v02.770 
2014-08-13
 
Confidential / Preliminary
 
The HSIC interface comprises 6 lines: 
•  Two  signal  lines  (strobe  -  HSIC_STRB  -  and  data  -  HSIC_DATA)  are  used  in  a  source 
synchronous serial interface with a 240MHz clock to provide a 480Mbps USB interface. The 
HSIC_STRB and HSIC_DATA lines are high-speed signals and should be routed as 50  
impedance traces. The trace length of these signals should be balanced to minimize timing 
skew and no longer as 100mm. 
•  Four signal lines for Link Power Management (LPM). For further power reduction, the USB 
HSIC interface supports LPM according to the USB 2.0 standard. The LPM defines power 
management  states  and  mechanisms  to  affect  state  changes  that  are  used  b  y  the 
AP_WAKEUP and CP_WAKEUP signal lines to efficiently manage bus and system power. 
To take advantage of the LPM feature, two further signals are needed to support power 
management state transitions - the SUSPEND and HOST_ACTIVE signals. 
2.1.11  PWM Interfaces 
The GPIO6 and GPIO7 interface lines can be configured as Pulse Width Modulation interface 
lines PWM1 and PWM2. The PWM interface lines can be used, for example, to connect 
buzzers. The PWM1 line is shared with GPIO7 and the PWM2 line is shared with GPIO6 (for 
GPIOs see 
Section 2.1.7
). GPIO and PWM functionality are mutually exclusive. 
2.1.12  Pulse Counter 
The  GPIO8  line  can  be  configured  as  pulse  counter  line  COUNTER.  The  pulse  counter 
interface can be used, for example, as a clock (for GPIOs see 
Section 2.1.7
). 
2.1.13  Status LED 
The GPIO5 interface line can be configured to drive a status LED that indicates different 
operating modes of the module (for GPIOs see 
Section 2.1.7
). GPIO and LED functionality 
are mutually exclusive. 
2.1.14  Fast Shutdown 
The  GPIO4  interface  line  can  be  configured  as  fast  shutdown  signal  line  FST_SHDN.  The 
configured FST_SHDN line is an active low control signal and must be applied for at least 10 
milliseconds.  If  unused  this  line  can  be  left  open  because  of  a  configured  internal  pull-up 
resistor.