Introduction 
 
Thanks for choosing the Vision
’s wireless shock sensor of the home security device. This 
sensor is a Z-Wave™  enabled device (interoperable, two-way RF mesh networking 
technology) and is fully compatible with any Z-Wave™  enabled network. Every mains 
powered Z-Wave enabled device acts as a signal repeater and multiple devices result in 
more possible transmission routes which helps eliminate 
“RF dead-sports” 
Z-Wave
™ enabled devices displaying the Z-Wave™ logo can also be used with it 
regardless of the manufacturer, and ours can also be used in other manufacturer
’s 
Z-Wave
™ enabled networks. This sensor detects the vibrations made by an intruder 
trying to break a window or door, and also detect tamper situations, it will send Z-Wave™ 
signal when vibrations or tamper situations are detected. 
 
Product Description and Specification 
 
*** For indoor use only *** 
 
Specification:
 
Package Content 
Protocol: Z-Wave™  (ZM3102N) 
Frequency Range:   
868.42MHz (ZS5101EU) 
908.42MHz (ZS5101US) 
921.42MHz (ZS5101BR) 
920.00MHz (ZS5101JP) 
865.22MHz (ZS5101IN) 
Operating Range: Up to 100 feet line of sight 
Operating Temp.: -15
°C~ 60°C (5°F~140°F) 
Battery: Panasonic CR123A * 1PC 
1pc    ZS 5101 Shock sensor 
1pc    Bracket Holder 
1pc    Adhesive tape for sensor 
3pc    Screw 
1pc    CR123A Lithium Battery 
1pc    Installation & Operation 
Manual 
 
Z-Wave Command Classes: 
COMMAND_CLASS_BASIC   
COMMAND_CLASS_ALARM_V2 
COMMAND_CLASS_ASSOCIATION_V2 (_V1 JP only)     
COMMAND_CLASS_BATTERY 
COMMAND_CLASS_MANUFACTURER_SPECIFIC 
COMMAND_CLASS_SENSOR_BINARY 
COMMAND_CLASS_VERSION 
COMMAND_CLASS_WAKE_UP_V2
 
Installation 
 
Notice: If you are installing the entire Z-
Wave™ system for the first time, please refer to 
the installation guide of Z-
Wave™ Interface Controller before installing ZS 5101 Shock 
Sensor.   
1. 
Install Battery: Use care when installing the battery. Press the locking tab on the top sensor 
cover, and then gently pull up the cover. Observe the correct polarity before insert the 
battery.   
2. 
After insert the battery, the LED will start to flash slowly, which means the sensor 
has not yet been 
“inclusion”. 
3. 
For 
“Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller 
into “inclusion” mode, and following its instruction to add the ZS 5101 to your 
controller.    To get in the “inclusion” mode, the distance between sensor and 
controller is suggested to be in one meter.    Press the program switch of ZS 5101 
for 1 second at least to be included. The LED on the ZS 5101 should go off, if not, 
please try again. 
 
For 
“Exclusion” from (removing from) a network: Put the Z-Wave™  Interface 
Controller into 
“exclusion” mode, and following its instruction to delete the ZS 5101 
from your controller.    Press the program switch of ZS 5101 for 1 second at least to 
be excluded.   
 
For 
“Association” :removing the cover of the ZS 5101 to get into the “Awake” 
mode, then put the Z-Wave™  Interface Controller into 
“Association”, and following 
its instruction to associate the ZS 5101 with other device. Close the cover back after 
“association” done, afterward the ZS 5101 will get into “Sleep” mode for power 
saving. Support one association group (5 nodes). 
”Awake” mode: it is to leave the “Sleep” mode by removing the cover of ZD5101, 
to allow the Z-
Wave™ Interface Controller to do “Inclusion”, “Exclusion”, 
“Association” and to reply and receive the commands from controller. 
 
4. 
Slide back the rear cover and screw fastening with the front cover, the LED should 
go off. 
 
5. 
Using the adhesive tape or fixing screws to fix the bracket holder with shock sensor. 
 
6. 
Sensitivity Adjustment:   
To increase sensitivity, turn the adjustment clockwise. 
To decrease sensitivity, turn the adjustment counter-clockwise. 
 
 
 
 
 
 
 
 
 
 
 
-2- 