Vision Automobile Electronics Industrial Co Ltd ZS5101US 사용자 설명서
Introduction
Thanks for choosing the Vision
’s wireless shock sensor of the home security device. This
sensor is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave™ enabled network. Every mains
powered Z-Wave enabled device acts as a signal repeater and multiple devices result in
more possible transmission routes which helps eliminate
technology) and is fully compatible with any Z-Wave™ enabled network. Every mains
powered Z-Wave enabled device acts as a signal repeater and multiple devices result in
more possible transmission routes which helps eliminate
“RF dead-sports”
Z-Wave
™ enabled devices displaying the Z-Wave™ logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer
’s
Z-Wave
™ enabled networks. This sensor detects the vibrations made by an intruder
trying to break a window or door, and also detect tamper situations, it will send Z-Wave™
signal when vibrations or tamper situations are detected.
signal when vibrations or tamper situations are detected.
Product Description and Specification
*** For indoor use only ***
Specification:
Package Content
Protocol: Z-Wave™ (ZM3102N)
Frequency Range:
Frequency Range:
868.42MHz (ZS5101EU)
908.42MHz (ZS5101US)
921.42MHz (ZS5101BR)
920.00MHz (ZS5101JP)
865.22MHz (ZS5101IN)
908.42MHz (ZS5101US)
921.42MHz (ZS5101BR)
920.00MHz (ZS5101JP)
865.22MHz (ZS5101IN)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15
°C~ 60°C (5°F~140°F)
Battery: Panasonic CR123A * 1PC
1pc ZS 5101 Shock sensor
1pc Bracket Holder
1pc Adhesive tape for sensor
3pc Screw
1pc CR123A Lithium Battery
1pc Installation & Operation
1pc Bracket Holder
1pc Adhesive tape for sensor
3pc Screw
1pc CR123A Lithium Battery
1pc Installation & Operation
Manual
Z-Wave Command Classes:
COMMAND_CLASS_BASIC
COMMAND_CLASS_ALARM_V2
COMMAND_CLASS_ASSOCIATION_V2 (_V1 JP only)
COMMAND_CLASS_BATTERY
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_SENSOR_BINARY
COMMAND_CLASS_VERSION
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_BASIC
COMMAND_CLASS_ALARM_V2
COMMAND_CLASS_ASSOCIATION_V2 (_V1 JP only)
COMMAND_CLASS_BATTERY
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_SENSOR_BINARY
COMMAND_CLASS_VERSION
COMMAND_CLASS_WAKE_UP_V2
Installation
Notice: If you are installing the entire Z-
Wave™ system for the first time, please refer to
the installation guide of Z-
Wave™ Interface Controller before installing ZS 5101 Shock
Sensor.
1.
1.
Install Battery: Use care when installing the battery. Press the locking tab on the top sensor
cover, and then gently pull up the cover. Observe the correct polarity before insert the
battery.
cover, and then gently pull up the cover. Observe the correct polarity before insert the
battery.
2.
After insert the battery, the LED will start to flash slowly, which means the sensor
has not yet been
has not yet been
“inclusion”.
3.
For
“Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller
into “inclusion” mode, and following its instruction to add the ZS 5101 to your
controller. To get in the “inclusion” mode, the distance between sensor and
controller is suggested to be in one meter. Press the program switch of ZS 5101
for 1 second at least to be included. The LED on the ZS 5101 should go off, if not,
please try again.
controller. To get in the “inclusion” mode, the distance between sensor and
controller is suggested to be in one meter. Press the program switch of ZS 5101
for 1 second at least to be included. The LED on the ZS 5101 should go off, if not,
please try again.
For
“Exclusion” from (removing from) a network: Put the Z-Wave™ Interface
Controller into
“exclusion” mode, and following its instruction to delete the ZS 5101
from your controller. Press the program switch of ZS 5101 for 1 second at least to
be excluded.
be excluded.
For
“Association” :removing the cover of the ZS 5101 to get into the “Awake”
mode, then put the Z-Wave™ Interface Controller into
“Association”, and following
its instruction to associate the ZS 5101 with other device. Close the cover back after
“association” done, afterward the ZS 5101 will get into “Sleep” mode for power
saving. Support one association group (5 nodes).
“association” done, afterward the ZS 5101 will get into “Sleep” mode for power
saving. Support one association group (5 nodes).
|
”Awake” mode: it is to leave the “Sleep” mode by removing the cover of ZD5101,
to allow the Z-
to allow the Z-
Wave™ Interface Controller to do “Inclusion”, “Exclusion”,
“Association” and to reply and receive the commands from controller.
4.
Slide back the rear cover and screw fastening with the front cover, the LED should
go off.
go off.
5.
Using the adhesive tape or fixing screws to fix the bracket holder with shock sensor.
6.
Sensitivity Adjustment:
To increase sensitivity, turn the adjustment clockwise.
To decrease sensitivity, turn the adjustment counter-clockwise.
To increase sensitivity, turn the adjustment clockwise.
To decrease sensitivity, turn the adjustment counter-clockwise.
-2-
-1-