ADC Telecommunications Inc. F0684-112 사용자 설명서

다운로드
페이지 236
Help Hot Line (U.S. only): 1-800-530-9960
7-3
D-620616-0-20 Rev F
CONFIDENTIAL
Safety Precautions
NOTE: The proper crimp tool and die must be matched by the connector 
type.
7.1.3
Distance Requirements
Table 7-1 shows the distances between Fusion Wideband components and related 
equipment.
7.2
Safety Precautions
7.2.1
Installation Guidelines
Use the following guidelines when installing TE equipment:
1.
Provide sufficient airflow and cooling to the equipment to prevent heat build-up 
from exceeding the maximum ambient air temperature specification. Do not com-
promise the amount of airflow required for safe operation of the equipment.
2.
If you are removing the system, turn it off and remove the power cord first. There 
are no user-serviceable parts inside the components.
Table 7-1
Distance Requirements
Equipment 
Combination
Cable Type
Cable Length
Additional Information
Repeater/BTS to 
Fusion Wideband 
Main Hub
Coaxial; N male 
connectors
3–6 m (10–20 ft) typical
Limited by loss and noise.
Refer to your link budget 
calculation.
10 m (33 ft) maximum
Limited by CE Mark require-
ments.
Fusion Wideband 
Expansion Hub to 
RAU
CATV 75 Ohm; 
shielded F male con-
nectors
• Minimum: 10 meters (33 ft)
• Maximum: 
130 meters (426 ft) for RG-59; 
140 meters (459 ft) for RG-6; 
235 meters (771 ft) for RG-11
Main Hub to Expan-
sion Hub
Multi-mode fiber: 
Single-mode fiber: 
SC/APC male con-
nectors
500 m (1640 ft.) maximum
6 km (19,685 ft.) maximum
Limited by 3 dB optical 
attenuation
RAU to passive 
antenna
Coaxial; N male 
connectors
1–3.5 m (3–12 ft) typical
Limited by loss and noise.
Refer to your link budget
calculation.