EA Polling Request (from Controller to Speed Sensor) 
Description 
Value 
Start ID 
0xEA 
Destination ID 
0x02 – 0xFE (2-254) 
Source ID 
0x01 
Check byte 
Bytes 1-4 sum to 0 (mod 256) 
 
 
Polled Mode for D0-D4 Formats  
 
The D0-D4 Formats described in Appendix A may also be used in polled mode.  If polled 
mode is selected (Setting 90), sending a 3 byte poll string of “*P<cr>”, (0x2A 0x50 0x0D) 
causes a return of the current target speed in the selected format.  These formats are 
only available in the RS-232 Stationary model. 
 