Carrier Add Instructions
68P64115A19
4
Mar 2003
1X SC 4812T-MC BTS Hardware Installation - Software Release R2.16.1.x
CONTROLLED INTRODUCTION
A-3
Table A-1 identifies the number of components needed when adding a
carrier. This matrix is for 3 Sector only.
Table A-1: 3 Sector Carrier Add Matrix
Add
Fan Add
BBX Add
PA Add 3X3
PA Add 4X4
MCC Add
PLC Filler Removal
CCCP PS
Carrier  
2
None
3
3
4
As Needed
3 or 4
None
Carrier  
3
3 or 4
3
3
 4
As Needed
None
Add 1
Carrier  
4
None
3
3
 4
As Needed
None
None
Table A-2: 3 Sector Carrier FRU Matrix
Add
BBX Add
PA Add 3X3
PA Add 4X4
MCC
Carrier 2
BBX 7, BBX 8, BBX 9
CLPA 2A, 2B, 2C
CLPA 2A, 2B, 2C, 2D
As Needed
Carrier 3
BBX 4, BBX 5, BBX6
CLPA 3A, 3B, 3C
CLPA 3A, 3B, 3C
3D**
As Needed
Carrier 4
BBX 10, BBX 11, BBX 12
CLPA 4A, 4B, 4C
CLPA 4A, 4B, 4C, 4D
As Needed
** Add C–CCP Power Supply #3 for a 3rd Carrier.
Adding a Carrier (3 Sector)
Follow the step–by–step procedure (Table A-3) to add a carrier to the SC
4812T–MC BTS frame.
Table A-3: Adding a Carrier
Step
Action
1
Remove the PA Fan Trays from the top slots of both PA Cages (see FRU Guide for removal
instructions– SC 4812T–MC FRU Guide 68P64115A20).
2
Remove the PLC Filler Panels from the PA Cages using T15 Torx driver.
NOTE
PLC Filler Plate is located in the second CLPA slot in all quadrants (see Figure A-1 and Figure A-2).
3
Follow the instructions in the FRU Guide for installing CLPA modules and PA Fan Trays in the
Carrier 2 locations indicated in Figure 22–2.
NOTE
PA Fan Trays are installed over CLPAs. PA Fan trays are not required in locations without CLPAs.
4
Add a 3rd C–CCP Power Suppy Card to the frame. Refer toinstall instructions (see FRU Guide – SC
4812T–MC  68P64115A20
5
Install BBXs and MCCs (see Table A-1) for required number corresponding to carrier of newly
installed CLPAs.
6
All PAs for the carrier under test must be INS during testing. For carriers not under test, key one BBX
per carrier to a minimum power level.