Remote Global Positioning Satellite (RGPS) Cabling
68P64115A19
–
4
Mar 2003
1X SC 4812T-MC BTS Hardware Installation - Software Release R2.16.1.x
CONTROLLED INTRODUCTION
2-24
Figure 2-11: Remote GPS Cabling Diagram
MMI
AMR A
Remote GPS
Antenna
Antenna
Surge
Protected
Punchblock
(Customer
supplied)
A1
A2
Cabling Run List
Table 2-13 provides a listing of the cables need for installing the Remote
GPS option.
GPS option.
Table 2-13: Remote GPS Cable Descriptions and Part Numbers
Cable
Label
Label
Part Number
Description
A
1
T472Ax
RGD Antenna to Punchblock Cable; x=A–F for
different A1 cable length 50 feet to 2000 feet
different A1 cable length 50 feet to 2000 feet
A
2
3086433H07
Punchblock to Site I/O board
Install RGPS Cable
Install each cable by referring to the cable run list in Table 2-13, the
cabling diagram in Figure 2-11, and the procedure in Table 2-14. If
lightning arrestors are used with the RGPS, refer to the site specific
documentation for cabling information.
cabling diagram in Figure 2-11, and the procedure in Table 2-14. If
lightning arrestors are used with the RGPS, refer to the site specific
documentation for cabling information.
NOTE
Site specific characteristics determine the GPS/LFR cabling that
is installed.
is installed.
Table 2-14: Installing the RGPS Cabling
Step
Action
1
Connect cables A1 and A2 into the punch block, as if they were part of the same cable, cut in the
middle maintaining color code and signal integrity..
middle maintaining color code and signal integrity..
2
2