Nokia Solutions and Networks T5DK1 사용자 설명서

다운로드
페이지 140
BTS 60 Degree Sector (6 Sector) Receive Path Cabling
68P64115A19
4
Mar 2003
1X SC 4812T-MC BTS Hardware Installation - Software Release R2.16.1.x
CONTROLLED INTRODUCTION
2-33
Table 2-23: Cables Needed for 120 Degree Sector Receive Path
Cable
Qty.
Part Number
Description
G
12
CGDS2212602
15 ft. Jumper Cable, N/M–N/M.
Table 2-24: Cable Run List for 60 Degree Sector Receive Path Cabling
Cable
Cable path connecting Lightning Arrestors
to BTS RX connectors
RX CONNECT
RX Ports Used
Quantity
6
MAIN
RX 1A–6A
Quantity
6
DIVERSITY
RX 1B–6B
Procedure
Install each cable by using the cable run list in Table 2-23, the cabling
diagram in Figure 2-14, and the procedure in Table 2-25. Each cable is
installed the same way.
Table 2-25: Installing the 60 Degree Sector Receive Path Cables
Step
Action
1
Attach the connector–equipped end of the cables to the BTS RX connectors.
2
Route the cables to the lightning arrestors.
3
Cut the cables to length and label them accordingly. Install connectors on the cables.
2