PC: 
Selects the microphone connected to the optional DMU-2000 Data 
Management Unit while using the FM mode. 
 
073 F3E 28 RPT 
Function: Sets the magnitude of the repeater shift on the 28 MHz band. 
Available Values: 0 ~ 1000 kHz 
Default Setting: 100 kHz 
 
074 F3E 50 RPT 
Function: Sets the magnitude of the repeater shift on the 50 MHz band. 
Available Values: 0 ~ 4000 kHz 
Default Setting: 1000 kHz 
 
MODE-RTY Group 
075 rtty R PLRTY 
Function: Selects normal or reverse Mark/Space polarity for RTTY receive operation. 
Available Values: nor/rEU 
Default Setting: nor 
 
076 rtty T PLRTY 
Function: Selects normal or reverse Mark/Space polarity for RTTY transmit operation. 
Available Values: nor/rEU 
Default Setting: nor 
 
077 rtty RTY OUT 
Function: Selects the receiver to be connected to the data output port (pin 1) of the 
RTTY jack. 
Available Values: nAin (Main)/Sub (Sub) 
Default Setting: nAin (Main) 
 
078 ryyt OUT LEL 
Function: Sets the FSK RTTY data output level at the output port (pin 1) of the RTTY 
jack. 
Available Values: 0 ~ 100 
Default Setting: 50