Digital Security Controls Ltd. 08GS3060L 사용자 설명서

다운로드
페이지 16
1
INTRODUCTION
The GS3060 is a backup wireless communicator that sends alarm system information to a System
III or System II receiver through a GSM/GPRS wireless network or to a standard land-line receiver
through the GSM voice channel. For use with listed compatible control units as indicated in the
control unit manufacturer's installation instructions.
Features
• Compatible with any listed panel that supports 4 or 10-digit Contact ID
• Simulates land line
• Switches automatically to GSM network in the event of land line trouble (line down)
• GSM Signal Indicator
• 4 programmable outputs
• Houses 12V - 1.2 Ah battery
• Case Tamper Output
• Land-line Overvoltage Protection
• Dual-Band GSM Radio
• 4 Programmable Inputs
• GPRS/Internet communication with Sur-Gard System III / II
• PTM Feature 4 phone numbers programmable for Contact ID Dialer
• 4 numbers programmable for Contact ID Dialer through GSM voice channels
Technical Specifications
The input voltage to the GS3060     can be drawn from the UL/ULC Listed Control Panel or provided by
an external UL Listed power supply rated for the application (external power-limited source).
NOTE: The power supply must be Class II, Power Limited.
Ratings
Power Supply Ratings
Power Supply Ratings
Power Supply Ratings
Power Supply Ratings
Power Supply Ratings
Input Voltage: ............................................................................................ 9 - 14V
DC
 (13.8V
DC
 typical)
Current: .............................. 120mA* (JP3 - OFF and internal battery required) or 500mA* (JP3 ON)
* Plus any current drawn from the GS3060 AUX+ terminal
Battery: ........................................................................ sealed, rechargeable type, rated 12V/1.2Ah
NOTE: Battery must be replaced every 3-5 years.
Recharging current: .................................................................................................................. 50mA
Cur
Cur
Cur
Cur
Currrrrrent consumption
ent consumption
ent consumption
ent consumption
ent consumption
Standby current: ...................................................................................................................... 120mA
Alarm (Transmitting) current: ................................................................................................... 450mA
PGM outputs: ....................................................................................... 4, open collector, rated 50mA
Operating frequency: ................................................................................................... 850/1900MHz
Antenna Gain: ........................................................................................................................... 2.0dBi
Envir
Envir
Envir
Envir
Environmental specifications
onmental specifications
onmental specifications
onmental specifications
onmental specifications
Operating temperature: .................................................................................. 0°C-49°C (32°F-120°F)
Humidity: .................................................................................  93%RH Maximum (Non-Condensing)
Mechanical specifications
Mechanical specifications
Mechanical specifications
Mechanical specifications
Mechanical specifications
Metal enclosure, painted; dimensions: ...................... 138mm x 224mm x 55mm  / 5.4” x 8.8” x 2.2”
Weight (without battery): ................................................................................................ 900g / 3.2oz
Internal Event Buffer (communications): .................................................. 256 Events (not viewable)
Maximum loop resistance of line between the device connected in series on T1/R1: ........ 1KOhm