Digital Security Controls Ltd. 15TL2553GRE 사용자 설명서

다운로드
페이지 38
Establishing a communication channel between the Communicator and the SCW is critical to ensuring the desired operation of
the two units. The following steps must be completed during the on- site installation. Program the following to ensure that the
Communicator and the panel will work together as intended.
Initial Programming of Communicator and SCW
1. Enter [*][8][Installer Code] [Section Number] for panel programming. Record any values that are modified from their
default, in the appropriate Programming Worksheets.
NOTE: When programming Toggle Options, the toggle is ON when the number is displayed and OFF when the number is not
dis played. (e.g., [1---5---], Toggle Options 1 and 5 are ON, all others are OFF).
2. Panel Section [167] Cellular/Ethernet Interface Communications ‘Wait for ACK’: Default value is: 060 seconds.
3. When the communicator is installed with the SCW panel, 4 telephone numbers are available to backup one another.
You can set up these 4 telephone numbers to perform in one of two ways: Backup dialling or Alternate dialling.
a. Backup dialling: each of the 4 telephone numbers will make 5 dialling attempts in turn, before an FTC trouble is dis-
played on the keypad.
b. Alternate dialling: each telephone number makes 1 dialling attempt before moving on to the next number, cycling
through each of the 4 numbers for a total of 5 times each. If all 4 numbers fail the 5 attempts, an FTC trouble is dis-
played on the keypad.
4. Panel Sections [301], [302], [303], and [305] can be configured as Primary communication paths.
a. Panel Sections [302], [303], and [305] may also be configured for backup or redundant communications by using
Panel Section(s) [383] or [351] - [376]. Refer to the SCW panel Installation Manual for more information.
b. If a valid telephone number is programmed, communications will use Public Switched Telephone Network (PSTN).
Entering a 4 digit hexadecimal value for a telephone number will change the call routing to the Communicator, as
determined by the number programmed:
DCAAF: Internal (All Receivers). Signals will be routed depending on Section [851] [006] programming.
DCBBF: Ethernet Receiver 1 (Primary). (Not available for 3G2055(R)-E).
DCCCF: Ethernet Receiver 2 (Backup). (Not available for 3G2055(R)-E).
DCDDF: Cellular Receiver 1 (Primary).
DCEEF: Cellular Receiver 2 (Backup).
NOTE: Add a single ‘F’ as a suffix to the 4 digit hex number to populate the unused remainder of the 32 character field.
5. Panel Section [350]: If any of the phone numbers have been programmed as DCAA, DCBB, DCCC, DCDD, or DCEE,
panel Section [350] must be set to [04] if SIA format or [03] if Contact ID (CID) format is used by control panel.
6. Panel Section [382]: Toggle Option [5], ‘GS/IP Module Enabled’, must be set to ON.
7. Panel Section [401]: Toggle Option [1] must be set to ON in order to perform panel DLS session through Cellular or Eth-
ernet data channel.
8. Panel section [310], account code, auto syncs with the communicator account code in section [021]. The panel account
code ([*][8][installer code] [310]), will overwrite the communicator account code section ([*][8][installer code] [850] [021]) if
programmed differently.
NOTE: Keep a record of the SIM card telephone number, it is required by users for SMS Command and Control functions.
(The number can be recorded in the Programming Worksheets Section of this document, under Option [996]). Due to
the nature of the SIM card activation process with Cellular network carriers, it can take up to 24 hours for SIM card activ-
ation to be complete.
SMS Command and Control Functions
SMS Command and Control is available on SCW9055/57 panels. Users can send SMS text messages from their mobile phone
to the GSM phone number assigned to their system. Commands are only accepted from telephone numbers that have been
programmed in Sections [311]- [318]. The system will reject messages sent from telephone numbers that are not on the pro-
grammed list.
When the received SMS text matches a valid Section message, the function is performed on the control panel. Text messages
are not case sensitive and extra spaces are ignored. A User Access Code may be required for some SMS messages.
The SMS Message format is in 3 parts: Command, Partition Label (or only the partition number), and Access Code.
If an Access Code is included in the message, it is sent to the control panel for validation, along with the requested function.
If the panel is configured to require an Access Code and the code is not sent (or invalid) the panel will fail the function (unsuc-
cessful).
If the panel fails the function, an SMS response message is sent to the user. The SMS response will echo the command sensat,
followed by the label “unsuccessful”. (e.g., “night arm partition 2 1234 unsuccessful”).
The partition label or partition number may be excluded from the SMS request in a single partition system (e.g., disarm 9123).
NOTE: The GSM phone number can be viewed in Section [851] [996], and/or [851] [229] or by entering *6, then scrolling down
to “SMS Programming” and scrolling down to “Cellular phone No”.
Label Programming for SMS Message
Programmable Labels can not be modified in Connect24, use DLS IV for label programming only, if labels need to be mod-
ified. Before initiating remote programming, record your network’s Public IP Address and port for incoming DLS IV con-
nections.
11