Communicator Configuration with SCW
Figure 1: Communication Board Connection Points
Mounting 
Hole
Mounting 
Hole
SIM Card Holder
RJ-45 
Connector
(TL2553G(R)-E only)
UA684
NOTE: The Alarm Communicator is installed in the SCW prior to shipment by Digital Security Controls (DSC). The Factory
Installation includes insertion of the SIM card. The SCW should not be mounted in its final location without performing a
Communicator Test to ensure adequate HSPA/3G coverage for the 3G2055 (R)- E and TL2553G (R)- E Alarm Com-
municators
Installation Location
The Communicator shall be installed in an indoor location only.
This HSPA/3G/Ethernet Communicator shall be installed by Service Persons only. (Service Person is defined as a person hav-
ing appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in
performing a task and of measures to minimize the risks to that person or other persons). The Communicator shall be installed
and used within an environment that provides the pollution degree max 2, over voltages category II, in non-hazardous, indoor
locations only. This manual shall be used with the Installation Manual of the alarm control panel which is connected to the
HSPA/3G/Ethernet Communicator. All instructions specified within the control panel manual must be observed.
All the local rules imposed by local electrical codes shall be observed and respected during installation.
Installing CAT 5 Cable (TL2553G(R)-E only)
A Category 5 (CAT 5) ethernet cable must be run from a source with Ethernet/Internet connectivity to the Communicator mod-
ule, inside the Self Contained Wireless Control Panel cabinet. The Communicator end of the cable must have an RJ-45 plug,
which connects to the Communicator’s RJ-45 jack. All requirements for installation of CAT5 ethernet cable must be observed
for correct operation of the Communicator, including, but not limited to, the following:
l
Do NOT strip off cable sheathing more than required for proper termination.
l
Do NOT kink/knot cable.
l
Do NOT crush cable with cable ties.
l
Do NOT untwist CAT5 pairs more than 1.2cm (½”).
l
Do NOT splice cable.
l
Do NOT bend cable at right angles or make any other sharp bends.