Circuit Board Pinouts 
The AMS-1140 pedestals each have a circuit 
board in their bases. Figure 1 and Figure 2 show 
the location of connectors, LEDS, jumpers, and 
fuses, as well as pinouts for the connectors. 
Figure 2. Secondary pedestal capacitor board 
(0312-3075-01) pinouts 
 
Service Procedures 
This section covers the setup and service of the 
AMS-1140 detector. 
Field Replaceable Units 
The AMS-1140 has the following Field 
Replaceable Units (FRU): 
Secondary capacitor board 
0312-3075-01 
Interconnect cable 
0652-0506-01 
Pedestal installation kit 
0352-0444-01 
Alarm lens installation kit  
0352-0444-02 
Replacing the Secondary Cap 
Board 
WARNING—RISK OF ELECTRIC 
SHOCK!
 Disconnect AC power when 
servicing. 
1.  Turn off power to the pedestal at the circuit 
breaker. 
2.  Remove the cover from the exit side of the 
secondary pedestal. To do this: loosen the four 
fasteners at the base of the cover, and then lift 
the bottom of the cover up and then off the 
base.  
3.  On the secondary board, disconnect the Tx Coil 
cable from connector P1 and the primary 
pedestal from connectors P2. Pull on the 
connectors, not the wires.  
4.  Loosen two fasteners securing the capacitor 
board and remove it from the base cover. 
Retain the insulator for the replacement board. 
5.  Use the two fasteners to secure the new 
capacitor board to the base cover. 
6.  Reconnect the two cables to the capacitor 
board. 
7.  Put the cover back on the base, ensuring that 
you do not pinch any cables.  
8.  Tighten the four screws holding the base cover. 
 
Tx Coil Connector  
Interconnect 
cable connector 
Secondary 
Tuning jumpers 
P1 
J2 
P2 
J1 
Pin  Signal   
Color 
TX   
 
White 
GND 
 
Shield 
TX RETURN Black 
 
Pin  Signal   
Color 
TX   
 
White 
GND 
 
Shield 
TX RETURN Red or Black