Laird Controls North America Inc. 818A 사용자 설명서

다운로드
페이지 45
Command Pro Engineered Systems 
User Manual 
30    
142134 
6.7.3  22R08A Installation Testing 
Before putting the system into service, perform the following testing procedure: 
1.  Apply the appropriate power to the receiver (12-24 VDC or 120 VAC). 
2.  Verify that the POWER (DS3) LED turns ‘ON’. Refer to 
. 
3.  Turn on the transmitter. 
4.  Verify that the Signal (DS1) LED flashes. 
5.  Verify that pressing any function switch on the transmitter lights the corresponding relay on the 
receiver and the Relay (DS2) LED. 
Review all of the steps above to ensure the accuracy of the wiring. 
 
Figure 15: 22R08A LED Status Indicators