Honeywell International Inc. RTA-50D 사용자 설명서

다운로드
페이지 103
MAINTENANCE MANUAL
965-1696
Table 1001. Front Panel Functional Self-Test Results (Cont)
Mode
RTA-50D
Power
VDR
Status
Control
Fault
Antenna
Fault
Reported
Condition
Possible
Corrective
Action
Comment
General
fault
On
Off
Off
Off
1. Breaker
malfunction
2. LRU
malfunction
1. Check
aircraft
breaker to
LRU
2. Reapply
power to
LRU, remove
if condition
repeats
1. Power
not reaching
LRU due
to breaker
problem or
2. LRU
has internal
malfunction
External
fault
(control)
On
Green
Amber
Off
1. RTP
and/or CMC
controller not
present
2. Internal
malfunction
of RTP/CMC
interface
1. Check
aircraft RTP
and CMC
controllers
and/or
connections
2. Press
functional
self-test
button,
remove if
condition
repeats
1. RTP
and/or CMC
controller is
not present or
2. LRU
has internal
malfunction
of RTP/CMC
interface
1
External
fault
(antenna)
On
Green
Off
Amber
1. Antenna is
not present.
2. Internal
malfunction
of antenna
interface.
1. Check
aircraft
antenna,
and antenna
connection
2. Press
functional
self-test
button,
remove if
condition
repeats
1. Antenna
or antenna
connection is
not present or
2. LRU
has internal
malfunction
of antenna
interface
2
External
fault
(control
/antenna)
On
Green
Amber
Amber
Refer to
external
(control) fault
and external
(antenna)
fault
Refer to
External
(control) fault
and external
(antenna)
fault
Refer to
external
(control) fault
and external
(antenna)
fault
EFFECTIVITY
ALL
23-20-59
Page 1003
1 Mar 2011
© Honeywell International Inc. Do not copy without express permission of Honeywell.