Honeywell International Inc. RTA-50D 사용자 설명서

다운로드
페이지 103
MAINTENANCE MANUAL
965-1696
Table 1001. Front Panel Functional Self-Test Results (Cont)
Mode
RTA-50D
Power
VDR
Status
Control
Fault
Antenna
Fault
Reported
Condition
Possible
Corrective
Action
Comment
Internal
fault
(boot)
On
Amber
Amber
Amber
LRU did not
complete
boot
sequence
Reapply
power to
LRU, remove
if condition
repeats
Boot
sequence
did not
complete due
to internal
malfunction
Internal
fault
On
Red
Off or
Amber
Off or
Amber
LRU reports
internal
malfunction
1. Press
functional
self-lest
button
2. If condition
repeats,
reapply
power to LRU
3. If condition
repeats,
remove LRU
LRU has
detected
internal
malfunction
EFFECTIVITY
ALL
23-20-59
Page 1004
1 Mar 2011
© Honeywell International Inc. Do not copy without express permission of Honeywell.