Display mode
There are three modes of display operation. 
factory Settings
You can restore the configuration of your amplifier to the 
factory original settings, changing the input names to those 
listed above, setting the display mode to ‘small input names’ 
and setting all input sensitivity trim settings to 0dB.
To restore the settings, first disconnect the power cord from 
the amplifier. Hold down the setup key on the front panel 
and re-connect the power cord.
The ‘small input’ setting will show a 
three line display with the volume 
reading at the top of the display, 
the  selected  input  in  the  display 
centre  and  the  current  sample 
rate/lock  status  at  the  bottom 
when a digital input is selected.
The ‘large input’ setting will show 
a two line display with the volume 
reading  at  the  top  and  a  larger 
input legend below. 
The  ‘large  volume’  setting  will 
display large volume characters at 
the bottom of the screen with the 
bargraph above. 
Input sensitivity offset
It is possible to adjust the relative 
sensitivity  of  individual  inputs 
by  selecting  the  appropriate 
trim  option  from  the  menu.  This 
enables  the  volume  level  when 
playing low or high output source 
components such as tape decks or 
tuners  to  be  equalized  between 
system sources.
-27
CD
-27
-27dB
Offset
Input 7
+4dB
-27
CD
Sample rate 44.1kHz