Chapter 13. Maintenance and Troubleshooting
527
Draft Document for Review January 29, 2013 12:52 pm
8068ch13-Maintenance and Troubleshooting.fm
Table 13-3
Node canister status LED statues
3. If the power LED is on solid, consider the states of the fault LEDs 3 and 4 for each node
canister, as shown in Table 13-4
Table 13-4 Node canister fault LED states
4. If the canister fault LED and the internal fault LED do not indicate a problem, consider the
state of the battery LEDs 5, 6, and 7, as shown in Table 13-5 on page 528 on each node
canister. The canister will not run as part of the IBM Flex System V7000 unless it is sure it
can save its state and cache data in the event of power loss to the canister. See
Understanding the battery operation for the node canister.
canister. The canister will not run as part of the IBM Flex System V7000 unless it is sure it
can save its state and cache data in the event of power loss to the canister. See
Understanding the battery operation for the node canister.
LED
layout
layout
LED Name
Color
States
Canister status
Green
OFF – The IBM Flex System V7000 system code is not running. If the
Power LED is ON, the operating system has not started the IBM Flex
System V7000 system code yet. This state is normal just after the
canister is powered on. If it persists for more than 10 minutes, check
the canister status using the CMM.
Power LED is ON, the operating system has not started the IBM Flex
System V7000 system code yet. This state is normal just after the
canister is powered on. If it persists for more than 10 minutes, check
the canister status using the CMM.
ON SOLID – The canister is active and able to perform I/O as part of a
IBM Flex System V7000. The IBM Flex System V7000 management
GUI is available if any node canister in the system has its status LED
ON. Do not power off, or remove, a node canister whose status LED is
on solid. You might lose access to data or corrupt volume data. Follow
the proper procedure to shut down a node so that access to data is not
compromised.
IBM Flex System V7000. The IBM Flex System V7000 management
GUI is available if any node canister in the system has its status LED
ON. Do not power off, or remove, a node canister whose status LED is
on solid. You might lose access to data or corrupt volume data. Follow
the proper procedure to shut down a node so that access to data is not
compromised.
BLINK – The canister is in candidate or service state and is not
participating in I/O. If possible, use the recommended action in the
event log event log shown by the management GUI to service the node
canister. If this is not possible, use the service assistant to determine
the state of the node canister and resolve any critical node errors that
stop the canister from becoming active.
participating in I/O. If possible, use the recommended action in the
event log event log shown by the management GUI to service the node
canister. If this is not possible, use the service assistant to determine
the state of the node canister and resolve any critical node errors that
stop the canister from becoming active.
9
LED
layout
layout
LED Name
Color
States
Canister fault
Amber
OFF – The node canister is operating correctly, or it has not been
possible to isolate an issue to the node canister.
possible to isolate an issue to the node canister.
ON SOLID – The node canister has failed and should be replaced. If it
is available, use the IBM Flex System V7000 management GUI event
log fix procedures to guide the replacement.
is available, use the IBM Flex System V7000 management GUI event
log fix procedures to guide the replacement.
Internal fault
Amber
There is a fault on one or more of the replaceable parts in the canister, it
has been determined that the part needs replacing.
Note: This LED only applies to the network adapters. (There may be one or
two of them.) Review the IBM Flex System V7000 Storage Node event logs
or the CMM to identify the network adapter that failed.
has been determined that the part needs replacing.
Note: This LED only applies to the network adapters. (There may be one or
two of them.) Review the IBM Flex System V7000 Storage Node event logs
or the CMM to identify the network adapter that failed.
OFF – There are no failures isolated to internal components of the
canister
canister
ON SOLID – Replace the failing network adapter
3
4