Rohde Schwarz Rohde & Schwarz HMO1002 2-channel oscilloscope, Digital Storage oscilloscope, 21-1002-RS00 데이터 시트

제품 코드
21-1002-RS00
다운로드
페이지 60
15
Vertical System
SETUP key in the GENERAL section, and then press the 
soft menu key PROBE COMP. This compensation wizard 
will guide you through all the important points of the probe 
compensation. After connecting a probe, you can select 
the respective analog channel via soft menu key CHAN-
NEL 1 (CH1) or CHANNEL 2 (CH2). The enclosed HZ154 
probe stylus allows you to set the probe trimmers to an 
optimal square wave shape. The compensation is perfor-
med at 1 kHz (LF) and 1 MHz (HF). Use the soft menu FULL 
SCREEN to hide the wizard help entries. Select NEXT STEP 
to toggle the wizard into the 1MHz HF compensation. If 
multiple probes are connected, you can switch the channel 
via soft menu key NEXT CHANNEL. Use the EXIT option to 
exit the wizard after a successful probe compensation.
If you would like to perform a manual compensation wit-
hout the compensation wizard, choose the UTIL menu in 
the Vertical control panel, then select the soft menu key 
PATTERN GEN. in the soft menu SQUARE WAVE (see 
chapter 10.2.1).
4 .5  Threshold Setting
On page 2|2 in the advanced MENU in the VERTICAL 
section you can set a THRESHOLD. This threshold defines
the level to detect a High or a Low if analog channels are 
used as source for the serial bus analysis or logic trig-
ger. After selecting this soft menu item, you can set the 
threshold using the universal knob or the KEYPAD key. 
With the soft menu key HYSTERESIS a range around the 
trigger threshold level can be set. If the signal jitters inside
this range and crosses the trigger level thereby, no trigger 
event occurs. With FIND LEVEL will automatically analyze 
the signal and find an approriate level.
4 .6  Naming a Channel
The last entry NAME in the VERTICAL menu opens a 
submenu which allows you to enter a channel name. This 
name will be displayed on the grid and the printout. Your 
first option is to switch the display on (ON) or off (OFF).
The next option includes the menu item LIBRARY. After 
selecting this option, you can use the universal knob to 
choose a name from several suggestions. The EDIT LA-
BEL key allows you to enter a completely new name or 
Fig. 4.3: Name selection
to customize the suggested name. You may enter up to 8 
characters. Use the ACCEPT key to confirm the name in
the editor. It will then be shown in the display. The name 
is assigned to that specific signal and will move alongside
any set offset value.