Panasonic TQ2SA12 PCB Mount Relay 12V 2 CO, DPDT TQ2SA12 데이터 시트
제품 코드
TQ2SA12
TQ SMD
1
ds_61020_0004_en_tqsmd: 101006J
SPECIFICATIONS
LOW-PROFILE
SURFACE-MOUNT RELAY
TQ SMD RELAYS
mm
inch
5.6
.220
9
.354
14
.551
FEATURES
• Low-profile: 6 mm
.236 inch
(Tape height: max. 6.5 mm
.256 inch
)
• Tape and reel package is available as standard packing style
• Surge withstand between contacts and coil: 2,500 V
• Breakdown voltage between contacts and coil: 1,500 V
• Capacity: 2 A
• High sensitivity:
• Surge withstand between contacts and coil: 2,500 V
• Breakdown voltage between contacts and coil: 1,500 V
• Capacity: 2 A
• High sensitivity:
2 Form C; 140 mW power consumption (Single side stable type)
Contact
Note:
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10V DC, 10mA
max. level])
actual load. (SX relays are available for low level load switching [10V DC, 10mA
max. level])
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
By resistive method, nominal voltage applied to the coil; contact carrying current:
2 A.
2 A.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
Nominal voltage applied to the coil, excluding contact bounce time without diode.
*
5
Half-wave pulse of sine wave: 6 ms; detection time: 10
μs
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10
μs
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in
Characteristics
Arrangement
2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
(By voltage drop 6 V DC 1 A)
75 m
Ω
Contact material
Au-clad AgNi type
Rating
Nominal switching capacity
(resistive load)
(resistive load)
2 A 30 V DC,
0.5 A 125 V AC
Max. switching power
(resistive load)
(resistive load)
60 W, 62.5 VA
Max. switching voltage
220 V DC, 125 V AC
Max. switching current
2 A
Min. switching capacity
(Reference value)
(Reference value)
#1
10
μA 10 mV DC
Nominal
operating
power
operating
power
Single side stable
140 mW (1.5 to 12 V DC)
200 mW (24 V DC)
300 mW (48 V DC)
300 mW (48 V DC)
1 coil latching
70 mW (1.5 to 12 V DC)
100 mW (24 V DC)
2 coil latching
140 mW (1.5 to 12 V DC)
200 mW (24 V DC)
Expected
life (min.
operations)
life (min.
operations)
Mechanical (at 180 cpm)
10
8
Electrical
(at 20 cpm)
(at 20 cpm)
2 A 30 V DC
resistive
resistive
10
5
1 A 30 V DC
resistive
resistive
2
×10
5
0.5 A 125 V
AC resistive
AC resistive
10
5
Initial insulation resistance*
1
Min. 1,000 M
Ω (at 500 V DC)
Initial
breakdown
voltage
breakdown
voltage
Between open
contacts
contacts
1,000 Vrms for 1 min.
(Detection current: 10 mA)
Between contact sets
1,500 Vrms for 1 min.
(Detection current: 10 mA)
Between contact and
coil
coil
1,500 Vrms for 1 min.
(Detection current: 10 mA)
Initial surge
voltage
voltage
Between open
contacts
(10
contacts
(10
×160 μs)
1,500 V (FCC Part 68)
Between contacts and
coil (2
coil (2
×10 μs)
2,500 V (Telcordia)
Temperature rise*
2
(at 20
°C)
Max. 50
°C
Operate time [Set time]*
3
(at 20
°C)
Max. 4 ms [Max. 4 ms]
Release time [Reset time]*
4
(at 20
°C)
Max. 4 ms [Max. 4 ms]
Shock resistance
Functional*
5
Min. 750 m/s
2
{75 G}
Destructive*
6
Min. 1,000 m/s
2
{100 G}
Vibration resistance
Functional*
7
200 m/s
2
{20G}, 10 to 55 Hz
at double amplitude of 3.3 mm
Destructive
294 m/s
2
{30G}, 10 to 55 Hz
at double amplitude of 5 mm
Conditions for
operation, transport
and storage*
operation, transport
and storage*
8
(Not freezing and
condensing at low
temperature)
condensing at low
temperature)
Ambient
temperature
temperature
–40
°C to +85°C*
3
–40
°F to +185°F
Humidity
5 to 85% R.H.
Unit weight
Approx. 2 g