PIC10(L)F320/322
TABLE 15-1:
ADC CLOCK PERIOD (T
AD
) V
S
. DEVICE OPERATING FREQUENCIES 
FIGURE 15-2:
ANALOG-TO-DIGITAL CONVERSION T
AD
 CYCLES 
ADC Clock Period (T
AD
)
Device Frequency (F
OSC
)
ADC
Clock Source
ADCS<2:0>
16 MHz
8 MHz
4 MHz
1 MHz
F
OSC
/2
000
125 ns
(1)
250 ns
(1)
500 ns
(1)
2.0 
s
F
OSC
/4
100
250 ns
(1)
500 ns
(1)
1.0 
s
4.0 
s
F
OSC
/8
001
0.5 
s
(1)
1.0 
s
2.0 
s
8.0 
s
(2)
F
OSC
/16
101
1.0 
s
2.0 
s
4.0 
s
16.0 
s
(2)
F
OSC
/32
010
2.0 
s
4.0 
s
8.0 
s
(2)
32.0 
s
(2)
F
OSC
/64
110
4.0 
s
8.0 
s
(2)
16.0 
s
(2)
64.0 
s
(2)
F
RC
x11
1.0-6.0 
s
(1,3)
1.0-6.0 
s
(1,3)
1.0-6.0 
s
(1,3)
1.0-6.0 
s
(1,3)
Legend:
Shaded cells are outside of recommended range.
Note
1:
These values violate the minimum required T
AD
 time.
2:
For faster conversion times, the selection of another clock source is recommended.
3:
The ADC clock period (T
AD
) and total ADC conversion time can be minimized when the ADC clock is derived from the 
system clock F
OSC
. However, the F
RC
 clock source must be used when conversions are to be performed with the 
device in Sleep mode.
T
AD
1 T
AD
2 T
AD
3 T
AD
4 T
AD
5 T
AD
6 T
AD
7 T
AD
8
Set GO bit 
Holding capacitor is disconnected from analog input
T
AD
9
T
CY
 - T
AD
ADRES is loaded, GO bit is cleared, 
ADIF bit is set, holding capacitor is 
Conversion starts 
b7
b4
b3
b2
b1
b0
b6
b5
On the following cycle: 
(typically 100 ns) 