Texas Instruments Evaluation Board for the LM25066I LM25066I-EVM/NOPB LM25066I-EVM/NOPB 데이터 시트

제품 코드
LM25066I-EVM/NOPB
다운로드
페이지 59
SNVS824C – JUNE 2012 – REVISED MARCH 2013
READ_VOUT (8Bh)
The READ_VOUT command is a standard PMBus
command that returns the 12-bit measured value of the
output voltage. Reading this register should use the coefficients shown in
Accesses to this command
should use the PMBus
read word protocol. This value is also used internally for the VOUT Under Voltage
Warning detection.
Table 18. READ_VOUT Register
Value
Meaning
Default
0h – 0FFFh
Measured value for VOUT
0000h
READ_IIN (89h)
The READ_IIN command is a standard PMBus
command that returns the 12-bit measured value of the input
current. Returns instantaneous current. Reading this register should use the coefficients shown in
Accesses to this command should use the PMBus
read word protocol. This value is also mirrored at (D1H)
Table 19. READ_IIN Register
Value
Meaning
Default
0h – 0FFFh
Measured value for IIN
0000h
READ_PIN (97h)
The READ_IIN command is a standard PMBus
command that returns the 12-bit measured value of the input
current. Returns average power Reading this register should use the coefficients shown in
. Accesses to
this command should use the PMBus
read word protocol. This value is also mirrored at (DFh)
Table 20. READ_PIN Register
Value
Meaning
Default
0h – 0FFFh
Measured value for PIN
0000h
READ_TEMPERATURE_1 (8Dh)
The READ_TEMPERATURE _1 command is a standard PMBus
command that returns the signed value of the
temperature measured by the external temperature sense diode. Reading this register should use the coefficients
shown in
Accesses to this command should use the PMBus
read word protocol. This value is also
used internally for the Over Temperature Fault and Warning detection. This data has a range of -256°C to +
255°C after the coefficients are applied.
Table 21. READ_TEMPERATURE_1 Register
Value
Meaning
Default
0h – 0FFFh
Measured value for TEMPERATURE
0000h
MFR_ID (99h)
The MFR_ID command is a standard PMBus
command that returns the identification of the manufacturer. To
read the MFR_ID, use the PMBus
block read protocol.
Table 22. MFR_ID Register
Byte
Name
Value
0
Number of bytes
02h
1
MFR ID-1
54h ‘T’
2
MFR ID-2
49h ‘I’
Copyright © 2012–2013, Texas Instruments Incorporated
39
Product Folder Links: