www.ti.com
BURST
I
PFM(LEAVE)
LOAD CURRENT
V(OUT)
I
PFM(LEAVE)
I
PFM(ENTER)
INDUCTOR CURRENT
SLVS658B – MARCH 2006 – REVISED FEBRUARY 2007
Figure 45. Typical Burst Operation in PFM Mode
The PFM operation is disabled and PWM operation set if one of the following events happen during PFM
operation:
1. The total burst operation time exceeds 10
µ
s, typ.
2. The output voltage falls below 2% of the target regulation voltage.
The PFM mode can be disabled through the serial interface to force the individual converters to stay in fixed
frequency PWM mode.
64
Copyright © 2006–2007, Texas Instruments Incorporated
Product Folder Link(s):