Texas Instruments TPS23752 Evaluation Module TPS23752EVM-145 TPS23752EVM-145 데이터 시트

제품 코드
TPS23752EVM-145
다운로드
페이지 25
EVM Assembly Drawings and Layout Guidelines
7.2
Layout Guidelines
Follow power and EMI/ESD best practice guidelines for the layout of the PoE front end. A basic set of
recommendations include:
Parts placement must be driven by power flow in a point-to-point manner; RJ-45, Ethernet transformer,
diode bridges, TVS and 0.1-
μ
F capacitor, and TPS23752 converter input bulk capacitor.
Make all leads as short as possible with wide power traces and paired signal and return.
No crossovers of signals are allowed from one part of the flow to another.
Observe spacing consistent with safety standards, like IEC60950, between the 48-V input voltage rails
and between the input and an isolated-converter output.
Place the TPS23752 over split, local ground planes referenced to VSS for the PoE input and to RTN
for the converter. Whereas the PoE side may operate without a ground plane, the converter side must
have one. Make sure no logic ground and power layers are present under the Ethernet input or the
converter primary side.
Use large copper fills and traces on SMT power-dissipating devices, and use wide traces or overlay
copper fills in the power path.
The DC/DC Converter layout benefits from basic rules, such as:
Pair signals, reducing emissions and noise, especially the paths that carry high-current pulses which
include the power semiconductors and magnetics.
Minimize the trace length of high current, power semiconductors, and magnetic components.
Use vertical pairing, where possible.
Use the ground plane for the switching currents carefully.
Keep the high-current and high-voltage switching away from low-level sensing circuits, including those
outside the power supply.
Maintain proper spacing around the high-voltage sections of the converter.
12
TPS23752EVM-145: Evaluation Module for TPS23752
SLVU753 – July 2012
Copyright © 2012, Texas Instruments Incorporated