Power Supply 1
(1.7 V to 6.5 V)
Oscilloscope /
Multimeter /
External Circuit
www.ti.com
Operation
JP1: Rail Voltages
The setting of these jumpers configures the threshold of the MONITOR VOLTAGE input, as listed in
.
Table 2. Monitor Voltage Input Configurations
Setting
Description
Short 1-2
Threshold set for monitoring 5.0-V rail
Short 3-4
Threshold set for monitoring 3.3-V rail
Short 5-6
Threshold set for monitoring 1.8-V rail
Short 7-8
Threshold set for monitoring 1.2-V rail
3
Operation
This section provides information about the operation of the TPS3808G01EVM.
3.1
General Operation
The TPS3808G01EVM can be configured as either a single- or dual-rail monitor. As a single-rail monitor,
the device triggers a reset when its own supply rail falls beneath a particular set threshold. As a dual-rail
monitor, the part triggers a reset when an external supply rail is below the threshold.
The TPS3808G01EVM can also be used to evaluate the fixed-voltage devices in the
with minimal changes to the board. These various configurations are described in detail in the following
sections.
3.1.1
Single-Rail Monitoring
To use the TPS3808G01EVM as a single-rail monitor, connect shorts on JP2 and JP4. Use JP1 to set the
desired level of the voltage rail to be monitored. JP3 can be used to set the duration of the reset signal, or
left open for a fixed 20-ms duration. Connect a power supply to VDD (J4), Monitor Voltage (J3), and GND
(J5 and J6). Connect the RST output (J1) to an oscilloscope, multimeter, or external circuit.
shows a diagram of the proper configuration for single-rail monitoring.
Figure 1. Using the TPS3808G01EVM as a Single-Rail Monitor