Texas Instruments EVM430-F6736 - MSP430F6736 EVM for Metering EVM430-F6736 EVM430-F6736 데이터 시트

제품 코드
EVM430-F6736
다운로드
페이지 124
MSP430F673x
MSP430F672x
SLAS731C – DECEMBER 2011 – REVISED FEBRUARY 2013
PMM, SVS Low Side
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
SVSLE = 0, PMMCOREV = 2
0
nA
I
(SVSL)
SVS
L
current consumption
SVSLE = 1, PMMCOREV = 2, SVSLFP = 0
200
nA
SVSLE = 1, PMMCOREV = 2, SVSLFP = 1
1.5
µA
SVSLE = 1, dV
CORE
/dt = 10 mV/µs,
2.5
SVSLFP = 1
t
pd(SVSL)
SVS
L
propagation delay
µs
SVSLE = 1, dV
CORE
/dt = 1 mV/µs,
20
SVSLFP = 0
SVSLE = 0
1, SVSLFP = 1
12.5
t
(SVSL)
SVS
L
on/off delay time
µs
SVSLE = 0
1, SVSLFP = 0
100
PMM, SVM Low Side
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
SVMLE = 0, PMMCOREV = 2
0
nA
I
(SVML)
SVM
L
current consumption
SVMLE = 1, PMMCOREV = 2, SVMLFP = 0
200
nA
SVMLE = 1, PMMCOREV = 2, SVMLFP = 1
1.5
µA
SVMLE = 1, dV
CORE
/dt = 10 mV/µs, SVMLFP = 1
2.5
t
pd(SVML)
SVM
L
propagation delay
µs
SVMLE = 1, dV
CORE
/dt = 1 mV/µs, SVMLFP = 0
20
SVMLE = 0
1, SVMLFP = 1
12.5
t
(SVML)
SVM
L
on/off delay time
µs
SVMLE = 0
1, SVMLFP = 0
100
Wake-Up from Low-Power Modes and Reset
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP MAX UNIT
f
MCLK
4 MHz
3
5
PMMCOREV = SVSMLRRL = n
Wake-up time from
t
WAKE-UP-
LPM2, LPM3, or LPM4
(where n = 0, 1, 2, or 3),
µs
1 MHz < f
MCLK
< 4
FAST
4
6
to active mode
(1)
SVSLFP = 1
MHz
Wake-up time from
PMMCOREV = SVSMLRRL = n (where n = 0, 1, 2, or 3),
t
WAKE-UP-
LPM2, LPM3 or LPM4 to
150
160
µs
SLOW
SVSLFP = 0
active mode
(2)
Wake-up time from
t
WAKE-UP-
LPM4.5 to active
2
3
ms
LPM4.5
mode
(3)
Wake-up time from RST
t
WAKE-UP-
or BOR event to active
2
3
ms
RESET
mode
(3)
(1)
This value represents the time from the wakeup event to the first active edge of MCLK. The wakeup time depends on the performance
mode of the low side supervisor (SVS
L
) and low side monitor (SVM
L
). Fastest wakeup times are possible with SVS
L
and SVM
L
in full
performance mode or disabled when operating in AM, LPM0, and LPM1. Various options are available for SVS
L
and SVM
L
while
operating in LPM2, LPM3, and LPM4. See the Power Management Module and Supply Voltage Supervisor chapter in the MSP430x5xx
Family User's Guide 
(
).
(2)
This value represents the time from the wakeup event to the first active edge of MCLK. The wakeup time depends on the performance
mode of the low side supervisor (SVS
L
) and low side monitor (SVM
L
). In this case, the SVS
L
and SVM
L
are in normal mode (low current)
mode when operating in AM, LPM0, and LPM1. Various options are available for SVS
L
and SVM
L
while operating in LPM2, LPM3, and
LPM4. See the Power Management Module and Supply Voltage Supervisor chapter in the MSP430x5xx Family User's Guide
(
).
(3)
This value represents the time from the wakeup event to the reset vector execution.
60