POWER-UP PROCEDURE
5
POWER-UP PROCEDURE
1. Apply 4.5 V - 18 V to JP7.
2. Toggle JP1 to enable V
OUT
1.
3. Toggle JP6 and JP5 to enable switch 1 and Switch 2 respectively.
4. Apply loads to the output connectors.
6
SCHEMATIC AND BILL OF MATERIALS
Figure 7. TPS65280EVM Schematic
7
SLVU722 – June 2012
TPS65280EVM User’s Guide
Copyright © 2012, Texas Instruments Incorporated