The PLL1 tab allows the user to change:
External VCXO (or XTAL oscillator) frequency. Note: This value must be entered in both the PLL1 and
PLL2 tabs.
PLL1 Phase detector frequency
PLL1 R-counter value
PLL1 N-counter value
CLKin (Reference) oscillator frequency
PLL1 Phase Detector polarity (external VCXO tuning slope)
PLL1 Charge pump gain
PLL1 Charge pump state.
Note that the value entered in the
Reference Oscillator frequency field on the PLL1 tab must match the
Reference Oscillator frequency entered on the PLL2 tab.