Texas Instruments UCD3138 Digital Power Factor Correction Pre-regulator Evaluation Module UCD3138PFCEVM-026 UCD3138PFCEVM-026 데이터 시트

제품 코드
UCD3138PFCEVM-026
다운로드
페이지 64
L
B
R
LOAD
R
L
Vin
Vout
R
D S_ON
V
sense
R
D1
R
D 2
C
P1
Gate
driver
Iref
Analog - to - PWM
Gain = 1
PID
Compensator
K
P
, K
I
, K
D
,
and T
s
R
S
R
3
R
4
C
P2
m
f
MIN(pk)
K
0.5 K
V
=
´
´
( ) (
)
REF
m
m
v
f
IN
2
RMS
1
I
K
A
C
B
K
U
K
V
V
æ
ö
ç
÷
=
´ ´ ´ =
´
´
´
´
ç
÷
è
ø
Digital PFC Description
12.8.1
Average Current Mode Control
The current loop is shown in the dashed line of
. The current reference signal I
REF
is calculated
as:
where
Km – multiplier gain
A – voltage loop output
B – 1/(V
IN(rms)
)2
C – V
IN
(1)
For sine wave input, the multiplier gain K
m
is expressed as,
(2)
In
Ks and Kf are scaling factors. For further detail, please refer to reference , and .
12.8.2
ZVS and Valley Control
Please refer to the reference and .
12.9 Current Feedback Control Compensation Using PID Control
A functional block diagram of single-phase PFC control loop is shown in
PID control is usually used in the feedback loop compensation in digitally controlled power converters.
Described below are several aspects using PID control in the single-phase PFC feedback control loop.
Figure 39. Single-phase PFC Feedback Loop Using PID Control
41
SLUU885B – March 2012 – Revised July 2012
Digitally Controlled Single-Phase PFC Pre-Regulator
Copyright © 2012, Texas Instruments Incorporated