Texas Instruments Clock Jitter Cleaner With Dual Cascaded PLLs and Integrated 2.2 GHz VCO LMK04805BEVAL/NOPB LMK04805BEVAL/NOPB 데이터 시트

제품 코드
LMK04805BEVAL/NOPB
다운로드
페이지 79
 
L M K 0 4 8 X X   E V A L U A T I O N   B O A R D   O P E R A T I N G   I N S T R U C T I O N S  
 
 
 
 
 
28 
values (shown in the PLL2 tab), and is given by: 
 
PLL2 N Total = VCO Divider * PLL2 N Prescaler * PLL2 N Counter 
 
Clicking on the cyan-colored PLL2 block that contains R, PDF and N values will bring the 
PLL2 tab into focus where these values may be modified, if needed.   
 
Clicking on the values in the box containing the Internal Loop Filter component (R3, C3, R4, 
C4) allow one to step through the possible values.  Left click to increase the component value, 
and right click to decrease the value.  These values can also be changed in the Bits/Pins tab. 
 
The Reference Oscillator value field may be changed in either the Clock Outputs tab or the 
PLL2 tab.  The PLL2 Reference frequency should match the frequency of the onboard VCXO or 
Crystal (i.e. VCO frequency in the PLL1 tab); if not, a warning message will appear to indicate 
that the PLL(s) may be out of lock, as highlighted by the red box in Figure 10. 
 
 
Figure 10: Warning message indicating mismatch between  
PLL1 VCO frequency (30.72MHz) and PLL2 reference frequency (122.88 MHz)