Test Procedure
7
Test Procedure
7.1
Line/Load Regulation and Efficiency Measurement Procedure
7.1.1
CPU
1. Set up EVM as described in
,
,
,
, and
2. Ensure no jumper shorts are on J46.
3. Ensure all other jumpers configuration settings in this section before 5Vin and 12VBAT are applied.
4. Ensure load is set to constant resistance mode and to sink 0 Adc.
5. Ensure S1 and S4 are in OFF position.
6. Add scope probe on the TP27 for CPU Vcore ripple measurement.
7. Ensure USB cable is connected between host computer and USB port (J42) on the EVM.
8. Increase 5Vin from 0 V to 5 V. Use V1 to measure 5Vin input voltage.
9. Increase 12VBAT from 0 V to 12 V. Use V2 to measure 12VBAT input voltage.
10. Double-click the TI-SVID-GUI_1_5_0_1.exe to launch the GUI program. The GUI window shown in
appears.
11. Push S4 to ON position to enable the VR_ON of TPS59640. VR_ON LED lights up.
12. Now you are ready to send SVID commends. The GUI at start-up defaults:
Address: 00 CPU, Commend: SetVIDslow, Payload: 1.05V
(The user can select the SVID commend by using the pulldown menu.)
13. Click send Commend, and the CPU CPGOOD LED lights up. See the GUI window as shown in
14. Measure V3: CPU Vcore at J14 and A1: 12VBAT input current
15. Vary CPU LOAD from 0 Adc to 90 Adc. The CPU Vcore must remain in load line.
16. Vary 12VBAT from 9 V to 20 V. The CPU Vcore must remain in line regulation.
17. Push S4 to OFF position to disable CPU Vcore controller.
18. Decrease LOAD to 0 A, and disconnect the LOAD from terminal J1, J5, and J6.
19. Disconnect V3 from J14.
20. Disconnect scope probe from TP27.
28
Using the TPS59640EVM-751 IMVP-7, 3-Phase CPU/1-Phase GPU SVID
SLUU796
January 2012
Power System
Copyright
©